This is a mirror of http://www.digital.co.uk/info_uk/Tech/cables.htm
While every effort has been made to ensure the accuracy of the material, Digital (UK) is not responsible for any inadvertent errors.
This guide has been produced by the Digital UK pre-sales Technical Support Group for use by Digital and its partners.
Only cables which are of current interest have been included, so the list of entries is not exhaustive. The contents have been sourced from previous guides, from technical publications, and, from in-house investigation. Where cable data is not easily resourced, the technical data is incomplete, but hopefully still of value.
Please note that this publication is for guidance only and does not include full engineering specifications.
Editor - Tony Thompson
Production - Howard James
UK Digital Pre-Sales Technical Support Group
General Notes - Ordering Codes
Speed and Distance Considerations
Digital's Standard Synchronous Connector
BC09R EtherWORKS Router Adapter Cable
BC09S EtherWORKS Router Adapter Cable
BC09T EtherWORKS Router Adapter Cable
BC09U Eicon PC RS232-C Modem Cable
BC09V Eicon HSI V.24 Modem Cable
BC09W Eicon HSI V.35 Modem Cable
BC09X Eicon HSI X.21 Modem Cable
BC12F DECbrouter 90 X.21 Adapter Cable
BC12G DECbrouter 90 V.35 Adapter Cable
BC12H DECbrouter 90 RS422 Adapter Cable
BC12J DECbrouter 90 EIA 530A Adapter Cable
BC12K DECbrouter 90 RS423 Adapter Cable
BC12L DECbrouter 90 RS232 Adapter Cable
BC13L Video Cable for Colour Monitor
BC13M Keyboard / Mouse Extender Cable
BC16C / BC16D DEC423 "Harmonica" Cables
BC19L V.35 Communications Cable
BC19M IBM PC Parallel Interface Cable
BC19N EIA-232 "One-To-Four" Cable
BC19S Cable for Colour Monitor
BC19Y EIA-422 Null Modem Cable
BC22R EIA-232 Null Modem (CTS/RTS) Cable
BC22Z X.21 Communications Cable
BC23J Video Cable for Colour Monitor
BC27M Monochrome Monitor Cable
BC27Z RapidPrint 200 to Dataproduct Line Printer Cable
BC29T DSSI Cable for StorageWorks Cabinet
BC29U DSSI Cable for StorageWorks Cabinet
BC55D EIA-422/423 Communications Cable
BCC04 / BCC14 EIA-232 Modem Cables
BCC27 VRT13 Colour Monitor Cable
BCC45 PC Keyboard Extension Cable
BN24A Thin Wire Daisy Chain Cable
BN24B FDDI To FDDI Cable Assembly
BN24D FDDI To ST Cable Assembly
BN24Q 100BseT or 10BaseT Cable
BN26M High Performance Office Cable
BN26S Copper FDDI Cable (Shielded)
BN26U 10baseT Octopus Adaptor Cable
BN31K KZPSC Cable/Bulkhead Assembly
BN34A Dual ST-SC Fibre-Optic Cable <
BN34B Dual SC-SC Fibre-Optic Cable
BN34C Dual ST-ST Fibre-Optic Cable
BN34D MIC-SC Fibre-Optic Cable
BN41A DECserver900GM Octopus Cable
BN41B DECserver900GM Octopus Cable
BN41C DECserver900GM Adapter Cable
BN41D DECserver900GM Adapter Cable
BNE3x / BNE4x Transceiver Cable
BS19D EIA-232 Adapter Cable Kit
BS23V V.24 / V.28 Adapter Cable Kit
H8240-A UTP High Performance Data Grade Cable
H8240-B STP High Performance Data Grade Cable
H8245-A / H8246-A UTP Standard Data Grade Cable
H8245-C / H8246-C UTP High Performance Data Grade Cable
H8245-D / H8246-D STP High Performance Data Grade Cable
H8571-C/D Passive Adapter Wiring Diagram
Appendix A - EIA Standards, Speed and Distance
Appendix B - EIA-232 Signal/Pin Designations
Appendix C - Terminal Server Adaptors
Appendix D - OPEN DECconnect Sample Configurations
Appendix F - Ethernet Cable Parts
Appendix G - "Confusable" Cable Summary
Appendix H - Fibre Optic Notes
Appendix J - SCSI Device Connector Types
Appendix K - Summary of SCSI Cables
Appendix L - SCSI and
DSSI Terminators and Tri-link Adaptors
This table is provided for easy reference of cable by usage group, please note that it does not include all cables from the Cables Reference Guide.
BC06P Single-ended 50LD - 50LD
BC09D Single-ended, Transition 50LD - 50HD
BC09J Single-ended, Transition 50LD - 68HD
BC09K Single-ended 50LD - 50LD
BC19J Single-ended 50LD - 50LD
BC56H Single-ended, Transition 68HD - 50LD
BN21H Single-ended 50HD - 50HD
BN21J Single-ended 50HD - 50HD
BN21K Differential 68HD - 68HD
BN21L Differential 68HD - 68HD
BN21P VAXstation 3100 only 68HD - 50HD
BN21R Single-ended,Transition 50HD - 50LD
BN21V Single ended, "Y" 50HD + 2 X 50LD
BN21W Single ended, "Y" 68HD + 2 X 68 HD
BN21X Single Ended "T" 50HD + 2 X 68HD
BN21Y Single ended, "Y" 50LD + 2 X 50LD
BN23G Single-ended, Transition 50HD - 50LD
BN31K Wide Bulkhead Kit 68RCC - 68VHD
BN31L Single-ended 68VHD - 50HD
BN31M Single-ended 68VHD - 68HD
BN31S Single-ended 68VHD - 68HD
BN31V General Purpose Fast SCSI
BN31W General Purpose Fast SCSI
Appendix J - Summary of SCSI Device Connector Types
Appendix K - Summary of SCSI Cables
Appendix L - Terminators and Tri-link Adaptors
Where: 68HD is a 68-way High Density or Honda connector
50LD is a 50-way low-density or Centronics style connector
68VHD is a 68-way very high density (0.8mm pitch)
68RCC is a 68-way IDC Ribbon Cable Connector.
Appendix I DSSI Cabling Summary
Appendix L
Terminators and Tri-link Adaptors
BC09R Router RS232, RS422 Adapter
BC12N MemoryChannel
Link Cable
Communications
BC12F DECbrouter90 X.21 Adapter
BC12G DECbrouter90 V.35 Adapter
BC12H DECBrouter90 RS422 Adapter
BC12J DECBrouter90 EIA530 Adapter
BC12K DECBrouter90 RS423 Adapter
BC12L DECBrouter90 RS232 Adapter
BC22Z X.21/Kilostream Extension
BN41A DECserver900GM Octopus Cable
BN41B DECserver900GM Octopus Cable
BN41C DECserver900GM Adapter Cable
BN41D DECserver900GM Adapter Cable
BS19D DECWAN RS232 Adapter Kit
BS23V DECWAN RS232 Adapter Kit
BC22E Modem, RS232, Asynchronous
BC22F Modem, RS232, Synchronous
BC22R Null-Modem RS232, (CTS/RTS)
BC16K ThinWire patching BC16M ThinWire
Appendix F Ethernet Cable
Summary
10BaseT
Terminals/Printers (see also "DEC423")
BC27Z RapidPrint 200 to Dataproduct Line Printer Cable
BCC05 VT2xx or DECmate to Printer
BCC46 Apple Macintosh to Printer
BN24D MIC to ST (Bayonet)
BN24E ST to ST (Bayonet)
BN34A SC to ST (Push-pull)
BN34C ST to ST (Push-pull)
BN34D MIC to SC (Push-pull)
Power
BN26D General Purpose (See BN19A)
Monitor
Building/Office Cable supplied on reel.
H8240 Flat 6-conductors for DEC423 use.
H8240-A UTP High Performance Data Grade. Category 5.
H8240-B STP High Performance Data Grade. Category 5.
H8245-A UTP Standard Data Grade, (pvc). Category 3.
H8246-A UTP Standard Data Grade, (teflon). Category 3.
H8245-C UTP High Performance, high speed, Data Grade. Category 5.
H8246-C UTP High Performance, high speed, Data Grade, (teflon). Category 5.
H8245-D STP High Performance Data Grade. Category 5.
H8246-D STP High
Performance Data Grade (teflon)
Cable option numbers tend to be of the format:
BCxxx-yy or BNxxx-zz
where the "C" indicates that the suffix "yy" describes the length of the cable in feet, for example
BC21M-09...is a BC21M cable 9 feet long, and the "N" means the length "zz" is described in meters.
BN25B-30 is a BN25B cable 30 metres long.
Some cable options are prefixed with an "E0" identifier, this simply indicates the European origin of the cable, for example E0-BCC05-50 is a 50 feet long BCC05 sourced in Europe.
Other Cable Lengths
Letters may be used for cable lengths, eg,
A = 100,
B = 200,
C = 300,
D = 400,
E = 500,
H = 700,
L = 1000,
for example
-A5 = 150,
-B5 = 250,
-C0 = 300,
-H5 = 750,
-L0 = 1000, so.......
BN25B-H5 is a 750m BN25B cable, and BC22D-B5 is 250 feet long BC22D.
These letters may also be used to indicate decimals or feet and inches, thus BN19A-2E is a 2.5m BN19A, and BC26V-6D is a 6 feet 4 inches long BC26V.
BC06P
Description:
Single-ended SCSI cable.
Specification:
Number Of Conductors 50 conductors, plus shielding.
Connectors Two 50-way, low density, Centronics style, right-angled to the right connectors.
Wiring Pin to Pin.
Typical Usage To connect an RRD42 CDROM drive to a KZQSA adapter in a Q-bus host system.
Ordering Information BC06P-2F, BC06P-06, BC06P-09 (feet).
(17-02659-03, -02, -01)
BC09D
Description:
SCSI cable using single-ended electrical signals. This is a transition cable, so called because it
provides a transition between different connector types.
Important Note. Use the BN23G cable for fast SCSI applications. See BN23G for entry details.
Specification:
Connectors One male, 50-way, high-density, Honda, straight, with thumb latches. One male 50-way Centronics
style, low-density, straight, connector with bale locks.
Typical Usage To connect a BA350 StorageWorks storage shelf to a host system.
NOTE : As the BA350 shelf has a 50-way, high-density female connector which is directly on the
backplane, only a a cable with a straight 50-way, high-density male connector can be attached to it.
Ordering Information BC09D-03, -06, -12 (feet). (17-02641-01, -02, -03).
This cable is shipped with DECstation 5000 models 100 and 125.
BC09J
Description:
Single-ended, three feet long, SCSI cable.
Connectors One 50-way, low-density, Centronics style, right-angled connector; one 68-way, high density,
Honda, straight, female connector.
Ordering Information BC09J-03 (feet) (17-02443-01)
This cable is supplied along with the BC09K-02 in SZ12 Expansion Enclosures.
BC09K
Description:
Single-ended SCSI cable, two feet long.
Connectors Two 50-way, low-density, Centronics style, right-angled to the left connectors.
Typical Usage Connects SZ12 Expansion Enclosures together.
Ordering Information BC09K-02 (17 also shipped with the SZ16 Expansion Enclosure.
BC09R
Description:
"V" cable used to adapt the single serial communications port
of the DE206 EtherWORKS Router to one RS422, and one RS232 connection.
Each "leg" of the "V" is 3 feet in length.
Specifications:
Connectors 68-way high-density "Honda" male at the point of the "V",
with one
37-way D-type male, and one 25-way D-type male connector terminating each
"leg" of the
"V" cable.
Usage Adapts the 68-way multi-standard serial communications port of
the DE206-AA EtherWORKS
Router to one RS422 modem connection, and one RS232 modem connection. The
BC21G-02 RS422 to BT Kilostream
Adapter Cable may in turn be added to the 37-way RS422 end of the BC09R cable
for connection to a
Network Terminating Unit (NTU) for Kilostream use.
Ordering Information BC09R-03 (17-03133-01).
BC09S
Description:
"V" cable used to adapt the single serial communication port of the DE206
EtherWORKS Router to two RS232 connections.
Each "leg" of the "V" is 3 feet in length.
Specification:
Connectors 68-way high density, "Honda" male at the point of the "V", and two
25-way
D-type male connectors terminating each leg of the "V".
Usage Adapts the 68-way multi-standard serial communications port of the
DE206-AA EtherWORKS
Router to one or two RS232 modem connections.
Ordering Information BC09S-03 (17-03134-01).
BC09T
Description:
"V" cable used to adapt the single serial communications port of the DE206
EtherWORKS Router to two RS449/RS422 connections. Each "leg" of the "V" is 3
feet in length.
Specifications:
Connectors 68-way high density "Honda" male at the point of the "V", and two
37-way D-type male connectors terminating each leg of the "V".
Usage:
Adapts the 68-way multi-standard serial communications port of the DE206-AA
EtherWORKS Router to one or two RS449/RS422 modem connections. The BC21G-02
RS422 to BT Kilostream Adapter Cable may in turn be connected to one end of the
BC09T-03 cable for connection to a Network Terminating Unit (NTU) for Kilostream
use.
Ordering Information:
BC09T-03 (17-03135-01).
BC09U
Description:
A modem cable designed to connect the DS206-AA Eicon PC X.25
Network Controller to an RS232 modem.
Specification:
Connectors 25-way male D-type connector, with screw fixings, at both ends.
Ordering Information BC09U-10.
BC09V
Description:
A modem cable designed to connect the DS206-CA Eicon X.25 Network Controller
to a V.24 modem.
Specification:
Connectors 26-way male D-type connector at the DS206 controller end, 25-way
D-type male connector at the V.24 modem end. Both connectors have screw type
fixings.
Ordering Information BC09V-10.
BC09W
Description:
A modem cable designed to connect the DS206-CA Eicon PC X.25
Network Controller to a V.35 modem.
Specification:
Connectors 26-way male D-type connector at the DS206 controller end, 34-way
male
D-type connector at the V.35 end. Both connectors are secured with screw
fixings.
Ordering Information BC09W-10.
BC09X
Description:
A modem cable designed to connect the DS206-CA Eicon PC X.25
Network Controller to an X.21 leased line.
Specification:
Connectors 26-way male D-type connector at the DS206 controller end, 15-way
male
D-type connector at the X.21 end.
Both connectors are secured with screw fixings.
Ordering Information BC09X-10.
Description:
A 6 feet long cable designed to connect the DECbrouter 90 to a X.21 leased
line.
Specification: Wiring: Ordering Information:
BC12F-06 (17-03580-01)
Description:
A 6 feet long cable designed to connect the DECbrouter 90 to a V.35 modem.
Specification: Wiring where * indicates contacts are tied together.
Ordering Information:
BC12G-06 (17-03766-01).
Description:
A 6 feet long cable designed to connect the DECbrouter 90 to an RS422 modem.
Specification: Wiring where * indicates contacts are tied together.
** indicates a 120 Ohm resistor is connected between pins 13-38, and 10-35,
and 17-42; the resistors are located at Connector 1.
Ordering Information:
BC12H-06 (17-03767-01).
Description:
A 6 feet long cable designed to connect the DECbrouter 90 to EIA 530A.
Specification: Wiring where * indicates contacts are tied together.
** indicates a 120 Ohm resistor is connected between pins 13-38, and 10-35,
and 17-42; the resistors are located at Connector 1.
Ordering Information:
BC12J-06 (17-03760-01).
BC12K
Description:
A 6 feet long cable designed to connect the DECbrouter 90 to an RS423 modem.
Specification: Wiring where * indicates contacts are tied together.
Ordering Information:
BC12K-06 (17-03761-01).
BC12K
Description:
A 6 feet long cable designed to connect the DECbrouter 90 to an RS232 modem.
Specification:
Des 50-way, straight, micro-champ (DECbrouter end),
Connector 2 25-way, straight, male, D-type (RS232 end).
BC09R EtherWORKS Router RS232 & RS422 Adapter Cable
BC09S EtherWORKS Router RS232 Adapter Cable
BC09T EtherWORKS Router RS422 Adapter Cable
BC09U Eicon PC RS232-C Modem Cable
BC09V Eicon HSI V.24 Modem Cable
BC09W Eicon HSI V.35 Modem Cable
BC09X Eicon HSI X.21 Modem Cable
BC12F DECbrouter 90 X.21 Adapter Cable
Connectors Connector 1 50-way, straight, micro-champ (DECbrouter end),
Connector 2 15-way, straight, male, D-type (X.21 end).
Connector 1 (50-way) pin Connector 2 (15 way) pin Signal Name
1,2,26 - Code Ground *
-------------------------------------------------------------------
5 2 T(A) Tx Data A
30 9 T(B) Tx Data B
-------------------------------------------------------------------
6 5 I(A) DCD A
31 12 I(B) DCD B **
-------------------------------------------------------------------
8 3 C(A) RTS A
33 10 C(B) RTS B
-------------------------------------------------------------------
10 4 R(A) Rx Data A
35 11 R(B) Rx Data B **
-------------------------------------------------------------------
17 6 S(A) Tx Clock A
42 13 S(B) Tx Clock B **
-------------------------------------------------------------------
13,15 - Rx Clock A
DTE Clock A *
-------------------------------------------------------------------
38,40 - Rx Clock B
DTE Clock B *
-------------------------------------------------------------------
37 8 G DTE Ground
-------------------------------------------------------------------
where * indicates contacts are tied together (at Connector 1).
** indicates a 120 Ohm resistor is connected between pins
6-31, and 10-35, and 17-42; the resistors are located at
Connector 1.
BC12G DECbrouter 90 V.35 Adapter Cable
<
Connectors: Connector 1 50-way, straight, micro-champ (DECbrouter end),
Connector 2 34-way, straight, male, V.35 square (V.35 end).
Connector 1 (50-way) pin Connector 2 (34-way) pin Signal Name
1,26 - Code Ground *
4 E DSR A
------------------------------------------------------------------------
6 F DCD/I A
------------------------------------------------------------------------
9 D CTS A
------------------------------------------------------------------------
11 J Ring Indicate
------------------------------------------------------------------------
21 Y Tx Clock A
46 A Tx Clock B
-------------------------------------------------------------------------
22 U Clock A
47 W Clock B
--------------------------------------------------------------------------
23 R Rx Data A
48 T Rx Data B
--------------------------------------------------------------------------
24 P Tx Data A
49 S Tx Data B
-------------------------------------------------------------------------
25 V Rx Clock A
50 X Rx Clock B
-------------------------------------------------------------------------
32 C RTS
-------------------------------------------------------------------------
12,29 B DTE Ground *
------------------------------------------------------------------------
44 H DTR
------------------------------------------------------------------------
20 K Local Loop
------------------------------------------------------------------------
BC12H DECbrouter 90 RS422 Adapter Cable
Connectors: Connector 1 50-way, straight, micro-champ (DECbrouter end),
Connector 2 37-way, straight, male, D-type (RS422 end).
Connector 1 (50-way) pin Connector 2 (37-way) pin Signal Name
1,27 - Code Ground *
---------------------------------------------------------------------------------
4 11 DSR A
29 29 DSR B
----------------------------------------------------------------------------------
5 4 Tx Data A
30 22 Tx Data B
---------------------------------------------------------------------------------
6 13 DCD/I A
31 31 DCD/I B
---------------------------------------------------------------------------------
8 7 RTS/C A
33 25 RTS/C B
---------------------------------------------------------------------------------
9 9 CTS A
34 27 CTS B
---------------------------------------------------------------------------------
10 6 Rx Data A
35 24 Rx Data B **
----------------------------------------------------------------------------------
11 15 RI
---------------------------------------------------------------------------------
12 20 DCE Ground
---------------------------------------------------------------------------------
13 8 Rx Clock A
38 26 Rx Clock B **
---------------------------------------------------------------------------------
37 37, 19 DTE Ground *
---------------------------------------------------------------------------------
14 12 DTR A
39 30 DTR B
---------------------------------------------------------------------------------
15 17 Clock A
40 35 Clock B
---------------------------------------------------------------------------------
17 5 Tx Clock A
42 23 Tx Clock B *
---------------------------------------------------------------------------------
18 18 Test Indicate
---------------------------------------------------------------------------------
20 10 Local Loop
---------------------------------------------------------------------------------
41 16 Speed select
---------------------------------------------------------------------------------
45 14 Remote Loop
---------------------------------------------------------------------------------
BC12J DECbrouter 90 EIA 530A Adapter Cable
Connectors: Connector 1 50-way, straight, micro-champ (DECbrouter end),
Connector 2 25-way, straight, male, D-type (RS530A end).
Connector 1 (50-way) pin Connector 2 (25-way) pin Signal Name
1,26,27 - Code Ground *
---------------------------------------------------------------------------------
4 6 DSR A
---------------------------------------------------------------------------------
5 2 Tx Data A
30 14 Tx Data B
---------------------------------------------------------------------------------
6 8 DCD/I A
31 10 DCD/I B
---------------------------------------------------------------------------------
8 4 RTS/C A
33 19 RTS/C B
---------------------------------------------------------------------------------
9 5 CTS A
34 13 CTS B
---------------------------------------------------------------------------------
10 3 Rx Data A
35 16 Rx Data B **
---------------------------------------------------------------------------------
11 22 RI
---------------------------------------------------------------------------------
12 23 DCE Ground
---------------------------------------------------------------------------------
13 17 Rx Clock A
38 9 Rx Clock B **
----------------------------------------------------------------------------------
29,37 7 DTE Ground *
---------------------------------------------------------------------------------
44 20 DTR
---------------------------------------------------------------------------------
15 24 Clock A
40 11 Clock B
---------------------------------------------------------------------------------
17 15 Tx Clock A
42 12 Tx Clock B **
---------------------------------------------------------------------------------
18 25 Test Indicate
---------------------------------------------------------------------------------
20 18 Local Loop
---------------------------------------------------------------------------------
41 16 Speed select
---------------------------------------------------------------------------------
45 21 Remote Loop
---------------------------------------------------------------------------------
BC12K DECbrouter 90 RS423 Adapter Cable
Connectors Connector 1 50-way, straight, micro-champ (DECbrouter end),
Connector 2 37-way, straight, male, D-type (RS423 end).
Connector 1 (50-way) Connector 2 (37-way) Signal Name
pin pin
1,2,27 - Code Ground *
---------------------------------------------------------------------
4 11 DSR A
29 29 DSR B
---------------------------------------------------------------------
7 4 Tx Data
---------------------------------------------------------------------
6 13 DCD/I A
31 31 DCD/I B
---------------------------------------------------------------------
32 7 RTS/C
---------------------------------------------------------------------
9 9 CTS A
34 27 CTS B
---------------------------------------------------------------------
10 6 Rx Data A
35 24 Rx Data B
---------------------------------------------------------------------
11 15 RI
---------------------------------------------------------------------
12 20 DCE Ground
---------------------------------------------------------------------
13 8 Rx Clock A
38 26 Rx Clock B
----------------------------------------------------------------------
37 19,22,25,30,35,37 DTE Ground *
---------------------------------------------------------------------
44 12 DTR
---------------------------------------------------------------------
17 5 Tx Clock A
42 23 Tx Clock B
---------------------------------------------------------------------
18 18 Test Indicate
---------------------------------------------------------------------
20 10 Local Loop
---------------------------------------------------------------------
41 16 Speed select
---------------------------------------------------------------------
45 14 Remote Loop
---------------------------------------------------------------------
19 17 Clock
----------------------------------------------------------------------
BC12L DECbrouter 90 RS232 Adapter Cable
Connectors: Connector 1 <
Wiring
Connector 1 (50-way) pin Connector 2 (25-way) pin Signal Name 1,2 - Code Ground * ------------------------------------------------------------------------------ 4 6 DSR A ------------------------------------------------------------------------------ 6 8 DCD/I A ------------------------------------------------------------------------------- 7 2 Tx Data ------------------------------------------------------------------------------ 9 5 CTS A ------------------------------------------------------------------------------ 10 3 Rx Data A ------------------------------------------------------------------------------ 11 22 Ring Indicate ------------------------------------------------------------------------------ 13 17 Rx Clock A ------------------------------------------------------------------------------ 17 15 Tx Clock A ------------------------------------------------------------------------------ 18 25 Test Indicate ------------------------------------------------------------------------------ 19 24 Clock ------------------------------------------------------------------------------ 20 18 Local Loop ------------------------------------------------------------------------------ 32 4 RTS ------------------------------------------------------------------------------ 12,29,31,34,35,37,38,42 7 DTE Ground * ------------------------------------------------------------------------------ 41 23 Speed Select ------------------------------------------------------------------------------ 44 20 DTR ------------------------------------------------------------------------------ 45 21 Remote Loop ------------------------------------------------------------------------------
where * indicates contacts tied together.
Ordering Information:
BC12L-06 (17-03762-01).
Description 10 feet long MemoryChannel link cable.
Specification
Number of Conductors 100 conductors in 50 twisted-pairs.
Connectors Connector 1 : 100-way (50 x 2, dual inline pins), Male, D-type connector, with thumb-screws.
Connector 2 : 100-way (50 x 2, dual inline pins), Male, D-type connectors, with thumb-screws.
Typical Usage For connecting PCI-MC adaptor to PCI-MC adaptor
For connecting PCI-MC adaptor to MC-Hub
Ordering Information BC12N-10, p/n 17-04091-01
BC12N
BC13L
Description Colour Monitor cable 10 feet long.
Number of Conductors The cable terminates in five co-axial conductors, coloured red, green, blue, white and black.
Connectors 15-way, male, D-type, straight connector with three rows of pins, with fixing screws at the system end, and a BNC male connector at each of the five co-axial conductors at the monitor end. Each BNC connector is embossed with a R, G, B, H or V symbol, and is crimped onto the red, green, blue, white and black coductors respectively.
Typical Usage To connect a colour monitor to the Alpha range of servers and workstations.
Ordering Information BC13L-10 (30-34761-03)
BC13M
Description:
A 10 feet long cable to connect the mouse and the keyboard to specified workstations. It is supplied with the DECstation 5000 Model 240, and 1xx series machines, as the interconnect for the mouse and keyboard, and it may be purchased as an optional extra for the VAXstation 4000 models 60 and 90 to extend the mouse and keyboard cabling length.
Specification:
Connectors 15-way D-type female connector with screw fixings at the system box end: a junction box with a round 7-way mouse socket and an RJ12 4-way keyboard connector, at the mouse/keyboard end.
Ordering Information:
BC13M-10 (17-02640-01).
BC16C
Description:
The BC16C and BC16D cables are used in conjunction with the H3104 Cable Concentrator (Harmonica).
Specification:
PVC shielded, 1.5cm diameter.
Number Of Conductors 36, consisting of 18 twisted pairs.
Connectors BC16C - one right-angle 36-way centronics style connector, and one straight 36-way centronics connector.
BC16D - two right-angle 36-way centronics style connectors.
Wiring Pin to pin.
Pin Signal Pin Signal 1 Line 0 Tx+ 19 Line 0 Tx- 2 Line 0 Rx+ 20 Line 0 Rx- 3 Line 1 Tx+ 21 Line 0 Tx- 4 Line 1 Rx+ 22 Line 1 Rx- etc etc 15 Line 7 Tx+ 33 Line 7 Tx- 16 Line 7 Rx+ 34 Line 7 Rx- 17 Spare 35 Spare 18 Spare 36 Spare
Typical Usage To connect DECservers and communications controllers to the H3104 Cable Concentrator in order to provide eight DEC423 MMJ connectors.
NOTE : For DECserver 300 users, the BC16C/D cables will allow data-leads-only connections; it is NOT adequate when users want to utilise DSR/DTR connections which enable the DECserver 300 Autologout feature.
NOTE : To join two lengths of BC16C/D cables together the H3102-00 cable coupler may be used.
Ordering Information:
For both BC16C and BC16D :
E0-BC16C-10, -25, -50, -A0 (100ft), -B5 (250ft).
NOTE : The H3104-B adapter kit consists of a BC16C-10 cable, plus an H3104 Cable Concentrator. Two cable concentrator packages (P/N : 70-24313-01) containing a BC16D-25 and an H3104, are supplied with the CXA16 and CXB16 communication controllers.
BC16E
Description:
Terminal inconnection cable for use with DEC423 terminals and printers in an office environment. It is configured as a null-modem cable.
Specification:
Unshielded, flat, PVC insulation.
Number Of Conductors 6 conductors in a flat ribbon cable.
Connectors Two standard DEC423 Modified Modular
MMJ Connector
Plugs (MMPs). 6 pin connectors with offset lug.
Wiring Null modem.
Pin (Signal) To Pin (Signal) 1 DTR - 6 DSR 2 TD+ - 5 RD+ 3 TD- - 4 RD- 4 RD- - 3 TD- 5 RD+ - 2 TD+ 6 DSR - 1 DTR
Where :
TD+ is Transmitted Data
TD- is Transmitted Data Return
RD+ is Received Data
RD- is Received Data Return
Typical Usage: To connect DEC423 terminals and printers, and also EIA-232 (data lines only) devices with use of the appropriate H8571-x passive adapter.
Hardware:
Use the H8572 6-conductor cable extender to join BC16E cables together. To custom build BC16E cables to a desired length, use; H8240 DEC423 Office Cable (305 metre spool), and, H8220 Modified Modular Plugs (pack of 50), using the H8241 Crimp Tool to terminate the cable.
Ordering Information:
E0-BC16E-02, -10, -25, -50.
Description:
Length of RG58 ThinWire Ethernet cable for use as a patch cord in a Satellite Equipment Room (SER).
Specification:
Number Of Conductors: One co-axial.
Connectors: Male BNC style connector at each end.
Typical Usage:
There are 16 BC16K cables supplied with the H3118 ThinWire Patch Cord Kit, which is used in conjunction with the H3107-B ThinWire Patch Block.
Ordering Information:
E0-BC16K-02
BC16M
Description:
ThinWire co-axial cable for use with devices which have ThinWire BNC connectors. The maximum length of a ThinWire Ethernet segment is 185m.
Specification:
The pre-terminated BC16M cable has PVC insulation, but lengths of BC16M cable can be manufactured using either PVC or Teflon insulated cable.
Beldon 9907 for PVC, Beldon 89907 for Teflon. For IEEE 802.3. 10 Base 2, 10 Mb/s. Impedance: 50 ohms 20 AWG. Diameter 0.46cm. Minimum bending radius 4 cm.
Number Of Conductors:
One double screened co-axial conductor with foamed dielectric.
Connectors:
Two male BNC style connectors
Hardware:
Cables can be manufactured from lengths of H8243-A (PVC), or H8244-A (teflon) Thin Wire Cable on 305m spool, and E0-H8222 Co-axial connectors using the H8242 tool kit which contains the necessary crimping tool and strippers.
To correctly terminate a ThinWire segment use a E0-H8225 ThinWire Terminator. To connect a node to a ThinWire segment use a E0-H8223-00 'T' Connector. To join two BC16M cables together, use a E0-H8224 Barrel Connector.
Ordering Information:
E0-BC16M-06, E0-BC16M-15,
E0-BC16M-30
BC19B
Description:
EIA-422 synchronous adapter cable. To adapt Digital's 50 pin synchronous connector to EIA-422.
Specification:
Number Of Conductors: 28.
Connectors: One 50 way D-type female, and one 37 way D-type male.
Wiring:
50-Way Signal 37-Way 50-Way Signal 37-Way Pin Name Pin Pin Name Pin 1 CODE GROUND * 20 Tx CLOCK (A) 5 4 CODE 2 * 21 TX CLOCK (B) 23 6 Tx DATA (A) 4 34 DSR (A) 11 7 Tx DATA (B) 22 35 DSR (B) 29 9 RTS/C (A) 7 37 DCD/I (A) 13 10 RTS/C (B) 25 38 DCD/I (B) 31 11 Rx DATA (A) 6 39 CTS (A) 9 12 Rx DATA (B) 24 40 CTS (B) 27 13 LOCAL LOOP 10 41 DCE GROUND 20 15 TEST 1 18 44 DTE GROUND 19, 37 16 REM.LOOP 14 45 DTR (A) 12 17 RI 15 46 DTR (B) 30 18 Rx CLOCK (A) 8 47 CLOCK (A) 17 19 Rx CLOCK (B) 26 48 CLOCK (B) 35 50 SPEED 16
Where, * means the pins are connected together, and (A), (B) are A(+ve) and B(-ve) wires of a twisted pair.
Typical Usage:
DMB32, DEMSA, DSV11 connections for EIA-422. Use the BC55D extension cable for this adapter.
Ordering Information:
E0-BC19B-02 (17-01108-01).
BC19C
Description:
Synchronous adapter cable to adapt Digital's standard 50-way synchronous connector to X.21, or BT's Kilostream.
Specification:
Number Of Conductors
Connectors One 50-way female, and one 15-way male connector.
Wiring
50-Way 15-Way Signal 1, 2, 3 - Code Ground 6 2 Tx Data A 7 9 Tx Data B 9 3 Control A 10 10 Control B 11 4 Rx Data A 12 11 Rx Data B 18 7 Byte Timing A 19 14 Byte Timing B 20 6 Signal Timing A 21 13 Signal Timing B 37 5 Indication A 38 12 Indication B 44 8 DTE Ground Shell Shell Shield Braid and Drain Wire
Note : 0.5 W, 120 Ohm resistor between pins :
11 and 12, 18 and 19, 20 and 21, 37 and 38.
Typical Usage To connect a synchronous controller such as the DMB32. or DSB32 to X.21. Use the BC22Z to extend this cable.
IMPORTANT NOTE : The BC19C adapter cable may not be compatible with early BT Kilostream Network Terminating Units (NTU). When an older NTU is being used, the BC22X Kilostream adapter cable may be needed. Check with your telecom provider to determine the correct cable to use, quoting the cables' pinouts.
Ordering Information:
BC19C-02
BC19D
Description:
Synchronous adapter cable to adapt Digital's standard 50-way synchronous connector to V.24.
Specification:
This cable is a component part BS19D-02 V.24 synchronous adapter cable kit.
Number Of Conductors: 16.
Connectors: 50-way female D-type, 25-way male D-type.
Wiring
50-Way Pin Signal Name 25-Way Pin 50-Way Signal Name 25-Way Pin 1 CODE GROUND * 22 CLOCK 24 3 CODE 1 * 33 DTR 20 8 Tx DATA 2 34 DSR (A) 6 11 Rx DATA (A) 3 35 DSR (B) # 12 Rx DATA (B) # 36 RTS 4 13 LOCAL LOOP 18 37 DCD/I (A) 8 15 TEST 1 25 38 DCD/I (B) # 17 RI 22 39 CTS (A) 5 16 REM. LOOP 21 40 CTS (B) # 18 Rx CLOCK (A) 17 41 DCE GROUND # 19 Rx CLOCK (B) # 44 DTE GROUND 7,# 20 Tx CLOCK (A) 15 50 SPEED 23 21 Tx CLOCK (B) #
Where:
* means the pins are connected together,
# means connected to DCE ground, and,
(A), (B) are A(+ve) and B(-ve) wires of a twisted pair.
Typical Usage
To connect a synchronous controller such as the DEMSA, DMB32, DSV11, etc for V.24 use. Use with the BC22F extender cable.
Ordering Information
The BC19D-02 is a component part of E0-BS19D-02 which may be ordered.
BC19E
Description:
Adapter cable to adapt Digital's 50-way synchronous connector to EIA-423.
Specification:
Number Of Conductors: 24. 12 singles, 6 twisted pairs plus drain wire.
Connectors: One 50-way D-type female, one 37-way male D-type.
Wiring:
50-Way Pin Signal Name 37-Way Pin 50-Way Pin Signal Name 37-Way Pin 1 CODE GROUND * 3 CODE 1 * 8 Tx DATA 4 34 DSR (A) 11 11 Rx DATA (A) 6 35 DSR (B) 29 12 Rx DATA (B) 24 36 RTS 7 13 LOCAL LOOP 10 37 DCD/I(A) 23 15 TEST 1 18 38 DCD/I (B) 32 16 REM.LOOP 14 39 CTS (A) 9 17 RI 15 40 CTS (B) 27 18 Rx CLOCK (A) 8 41 DCE GROUND 20 19 Rx CLOCK (B) 26 50 SPEED 16 20 Tx CLOCK (A) 5 44 DTE GROUNDS 19 21 Tx CLOCK (B) 23 22 22 CLOCK 17 25 33 DTR 12 30 35 37
Where, * means the pins are connected together, and (A), (B) are the A(+ve), and B(-ve) wires of a twisted pair.
Typical Usage:
To connect a synchronous controller for EIA-423. Use with a BC55D extender cable.
Ordering Information:
BC19E-02.
BC19F
Description:
Synchronous adapter cable to adapt Digital's 50-pin sychronous connnector to V.35.
Specification:
Number of conductors: 17.
Connectors: One 50-way D-type female, one 34-way rectangular V.35 type male.
Wiring:
50-Way Pin Signal Name 34-Way Pin 50-Way Pin Signal Name 34-Way Pin 1 CODE GROUND * 31 V.35 Rx CLOCK (A) V 2 CODE 0 * 32 V.32 Rx CLOCK (B) X 17 RI J 33 DTR H 23 V.35 Tx CLOCK (A) Y 34 DSR (A) E 24 V.35 Tx CLOCK (B) A 35 DSR (B) # 25 V.35 CLOCK (A) U 36 RTS C 26 V.35 CLOCK (B) W 37 DCD/I (A) F 27 V.35 Rx DATA (A) R 38 DCD/I (B) # 28 V.35 Rx DATA (B) T 39 CTS (A) D 29 V.35 Tx DATA (A) P 40 CTS (B) # 30 V.35 Tx DATA (B) S 41 DCE GROUND # 44 DTE GROUND B, #
Where:
* means the pins are connected together
# means connected to DCE GROUND
(A), (B) wires are a(+ve), and b(-ve) of a twisted pair.
Typical Usage:
to connect a synchronous controller such as the DEMSA, DMB32, DSV11, ect for the V.35 use. Use with the BC19L extender cable.
Ordering Information:
E0-BC19F-02 (17-01112-01).
BC19J
Description:
Single-ended SCSI cable.
Specification:
Number Of Conductors 50 in 25 twisted pairs, plus screening.
Connectors Two 50-way, low-density, centronics style, straight connectors.
Typical Usage To daisy-chain SCSI devices.
Ordering Information:
The BC19J-1E, and the BC56H-03 are generally supplied with non-embedded SCSI devices.
The BC19J-1E is not available as a separate item.
BC19J-1E (1 foot 6 inches), BC19J-03, BC19J-06. (17-01351-04, 17-03151-01, 17-03151-02).
Description:
V.35 extension (modem) cable.
Specifications:
Number Of Conductors: 13.
Connectors: One 34-way male, one 34-way female.
Wiring: Straight through.
Typical Usage: Extension for the BC19F V.35 adapter cable.
Ordering Information:
BC19L-25.
BC19M
Description: This cable is designed to connect a Centronics type parallel printer to the parallel printer port of an IBM or IBM compatible PC.
Specification:
Shielded.
Number Of Conductors: 25
Connectors: 25-pin male D-type at PC end, 36-way male Centronics type at printer end. Both ends are straight.
Wiring:
25-way PC end. Signal 36-way Printer end. 1 Strobe to printer 1 2 Data Bit 1 - to printer 2 3 Data Bit 2 - to printer 3 4 Data Bit 3 - to printer 4 5 Data Bit 4 - to printer 5 6 Data Bit 5 - to printer 6 7 Data Bit 6 - to printer 1 CODE GROUND * 22 CLOCK 24 3 CODE 1 * 33 DTR 20 8 Tx DATA 2 34 DSR (A) 6 11 Rx DATA (A) 3 35 DSR (B) # 12 Rx DATA (B) # 36 RTS 4 13 LOCAL LOOP 18 37 DCD/I (A) 8 15 7 8 Data Bit 7 - to printer 8 9 Data Bit 8 - to printer 9 10 Acknowledge Low - from printer 10 11 Busy High - from printer 11 12 Paper End High - from printer 12 13 Error Low - from printer 13 14 Auto Feed Low - to printer 14 15 NOT USED 32 16 Initialise Low - to printer 31 17 Select Input Low 36 18 Ground 33 19 Ground 19 20 Ground 21 21 Ground 23 22 Ground 25 23 Ground 27 24 Ground 29 25 Ground 30
Ordering Information:
BC19M-10 (17-01516-01).
BC19M-06 (17-01516-02)
Description: Adapter cable assembly to provide four EIA-232 connections from a single outlet.
Specification:
Number Of Conductors 44
Connectors One 50-way male centronics style connector to four 25-way D-type male connectors.
Wiring The pin-outs for the 50-way connector are as follows :
Pins 1-11 are Channel 0 Pins 13-23 are Channel 1 Pins 25-35 are Channel 2 Pins 27-47 are Channel 3 Pins 12, 24, 36, 48, 49, and 50 are not used. Signal 50-Way Pins 25-Way Pins Transmitted Data 1 13 25 37 2 Received Data 2 14 26 38 3 Request To Send 3 15 27 39 4 Clear To Send 4 16 28 40 5 Data Set Ready 5 17 29 41 6 Signal Ground 6 18 30 42 7 Data Carrier Detected 7 19 31 43 8 (Not Used) 8 20 32 44 12 Data Terminal Ready 9 21 33 45 20 Ring Indicator 10 22 34 46 22 (Not Used) 11 23 35 47 25
Typical Usage:
Two BC19N cable assemblies are supplied with the CXY08 Communications Controller to enable the connection of the eight EIA-232 modem channels.
Ordering Information:
Not available as separate items.Two BC19N-12 (17-01399-01) cables are provided in the Cable Concentrator Package (70-24314-01) supplied with the CXY08 controller.
BC19S
Description:
VAXstation 3100 colour monitor cable, 10 feet long.
Specification:
15-way D-type, female connector with fixing screws at the system end, and connector block with screw fixing at the monitor end. The connector block has the following connectors:
* three BNC male connectors, on short leads, for the monitor. * 4-way keyboard socket. * 7-way socket for the mouse.
The 3 BNC connectors are embossed with the legend 'R', 'G', or 'B', and the short leads to which they are attached are colour coded red, green, or blue.
Typical Usage:
Used with VAXstation 3100 models 30, 38, 48 (colour - not SPX). Also used with the VAXstation 2000 (colour).
Ordering Information:
BC19S-10 p/n 17-01480-01
BC19Y
Description
The BC19Y is an EIA-422 Null Modem unit interconnect cable.
Specification
Connectors Two 50-way female D-type connectors.
Wiring Null modem.
Typical Usage To connect MUXserver 300 to DECmux 300, or, connects two DECmux 300s together.
Ordering Information BC19Y-10
BC21G
Description
RS422 to BT Kilostream adapter cable, designed for connection between the DNSXH-AC RS422 distribution panel of the DECNIS WANcontroller 318 (also used with the DE206-AA EtherWORKS Router) and BT Kilostream in the UK.
Specification
Number Of Conductors
Connectors One 37-way female D-type at the WANcontroller end, and one 15-way male D-type at Kilostreams NTU end.
Wiring
37-way Signal 15-way (Pin) (Pin) 4 Tx Data A 2 22 Tx Data B 9 7,9 Control A 3 25,27 Control B 10 6 Rx Data A 4 24 Rx Data B 11 8,5 Signal Timing A 6 26,23 Signal Timing B 13 13 Indication A 5 31 Indication B 12 19,37 DTE Ground 8 11,12 DSR A to DTR A 29,30 DSR B to DTR B 10,18 Local Loop to Test Indicate 15,16 DSRs to RI SHELL Shield Braid SHELL
Note : i) There is a 120 Ohm resistor between the following pins, at the 37-way connector :
6 and 24 - Rx Data 5 and 23 - Signal Timing 13 and 31 - Indication
Typical Usage
Connects an RS422 port of the DNSXH-AC distribution panel of the DECNIS WANcontroller 618, and also the EtherWORKS Router to BTs Kilostream.
Use the BC19C-02 to connect the DECNIS WANcontoller 622 to Kilostream.
Ordering Information BC21G-02 (17-03100-01)
BC21M
Description:
DSSI cable for inter-cabinet use.
Specification:
Connectors Two right-angled, female 50 way PS (Pedestal or Pin Socket) connectors with screw fixings.
Ordering Information BC21M-03, -09, -16, -25 (feet). (17-02152-01, -03, -04, -05).
BC21Q
Description DSSI cable for inter-cabinet use.
Specification
Connectors Two MR (Mid-Range) style, female, straight, 50-way connectors with screw fixings.
Typical Usage Connects VAX 6000, 7000, 9000, and 10000 systems to DSSI storage cabinets.
Ordering Information BC21Q-3F (3.5 feet), -06, -09, -25, -50 (feet) (17-02382-01, -09, -02, -05, -06, -10.)
The BC21Q-09 is a component part of both the CK-SF100-LM, and CK-SF200-LM cable kits. Also BC21Q-16 and BC21Q-25 are component parts of different variants of these kits.
BC22D
Description
The BC22D is a fully shielded, EIA-232 null modem cable designed for asynchronous applications.
Specification
Gauge: 24-AWG;
Shield: 36-AWG braid.
Number Of Conductors 6
Connectors Two 25 way female D-type.
Wiring Null modem.
Pin Signal Pin Signal 1 1 2 Transmit Data 3 Receive Data 3 Receive Data 2 Transmit Data 6 DSR 20 DTR 7 Signal Ground 7 Signal Ground 20 DTR 6 DSR
Typical Usage To connect EIA-232 terminals and printers to DECservers etc.
Ordering Information
E0-BC22D-10, E0-BC22D-25, E0-BC22D-50 E0-BC22D-A0, -B0, -B5.
Description
The BC22E is a fully shielded EIA-232 asynchronous modem cable.
Specification
Gauge: 24-AWG:
Shield: 36-AWG braid.
Number Of Conductors 16
Connectors One male and one female 25 way D-type.
Wiring Point to point for the following pins:
1, 2, 3, 4, 5, 6, 7, 8, 11, 12, 18, 19, 20, 22, 23, 25.
Typical Usage To connect to asynchronous modems, or to extend a BC22D null modem cable.
Ordering Information
E0-BC22E-02, E0-BC22E-10, E0-BC22E-25, E0-BC22E-50, -A0, -B0, -B5.
BC22F
Description
Fully shielded EIA-232 synchronous modem cable.
Specification
Gauge: 24-AWG;
Shield: 36-AWG.
Number Of Conductors 25
Connectors One male and one female 25 way D-type.
Wiring Point to point for all pins.
Typical Usage
For connection to synchronous modems, and as an extension for a BC19D cable.
Ordering Information
E0-BC22F-10, -25, -50, -A0, -B0, -B5.
Description
This 24 inch cable is fully shielded and was designed for use as a "gender changer".
Specification
Gauge: 24-AWG,
Shield: 36-AWG braid.
Number Of Conductors 25.
Connectors Two male 25 way D-type connectors, which are not molded on.
Wiring Point to point for all 25 connectors.
Typical Usage To adapt a cable by changing its gender at one end.
Ordering Information
BC22H-02
Description:
EIA-232 null modem cable designed for devices using CTS/RTS flow control.
Specification Shielded.
Number Of Conductors 10
Connectors 25-way female connectors at each end.
Wiring
Signal Pin Pin TD 2 3 RD 3 2 RTS 4 5 CTS 5 4 DTR 20 6,8 DSR, CD 8 20 RI 22 23 DSRS 23 22
Typical Usage
To connect host systems and devices using CTS/RTS flow control to the DECmux 300 EIA-232 user port.
Note : Use a BC17D cable to connect host systems and devices that do NOT use CTS/RTS flow control to the DECmux 300 EIA-232 user port.
Ordering Information BC22R-10, -25, -50, - A0.
BC22Q
Description:
DSSI cable for inter-cabinet use.
Specification:
Connectors
One MR (Mid-Range) style, female, straight, 50-way connector with screw fixings, one PS (Pin Socket) style, female, right-angled connector, also with screw fittings.
Typical Usage Connects VAX 4000, and Q-bus MicroVAX 3000 series systems to DSSI storage cabinets.
Ordering Information BC22Q-09, -16, -25, -50 (feet). (17-0271-01, -02, -03, -04).
The BC22Q-09 is not separately orderable.
The BC22Q-09 is a component part of both the CK-SF100-LP, and the CK-SF200-LP cable kits, also the BC22Q-16, BC22Q-25, and BC22Q-50 are component parts of different variants of these kits.
Description:
The BC22X is an adapter cable for adapting Digitals standard 50-way synchronous connector to early versions of BT's Kilostream network and Mercury Communications equivalent network when operating at 64 Kb/s using the X.21 (15 pin D-type) connector.
For newer installations the BC19C adapter cable will be required, see entry "BC19C". Check with your telecom provider for correct cable choice.
Specification:
Number Of Conductors 7
Connectors One 50 pin female, and one 15 way male connector.
Wiring
50-Way Signal 15-Way 1,4 Code Ground (RS422) - 6 Tx Data A 2 7 Tx Data B 9 11 Rx Data A 4 12 Rx Data B 11 20 Signal Timing A 6 21 Signal Timing B 13 9,37,39 RTS A, DCD A, CTS A - 10,38,40 RTS B, DCD B, CTS B - 13,15 Local Loop, Test Ind - 50,17 Speed Sel Incoming Call - 34,45 RSD A, DTR A - 35,46 DSR B, DTR B - 44 DTE Ground, Drain Wire 8 Shell Shield Braid and Drain Wire Shell
Notes :
i)120 Ohm resistor between pins 11 and 12.
ii) One 120 Ohm resistor between pins 18 and 20 tied together, and 19 and 21 are tied together.
Typical Usage For use with a synchronous controller,eg, DEMSA, DMB32, etc . Use the BC22Z to extend the BC22X adapter.
Ordering Information
Order the BC22X-02 from the manufacturer:
BIEN Data,
Crowmarsh Gifford,
Oxfordshire.
TEL 0491 826030
Description:
A cable designed to extend the BC22X X.21 adapter cable.
Specification
Number Of Conductors 12, 6 twisted pairs.
Connectors One 15-way D-type male, one 15-way D-type female.
Typical Usage Use as an extender cable for the BC22X X.21 adapter cable.
Ordering Inf1 E="bc2ormation
Order from BIEN Data (See BC22X entry for address).
BC23J
Description:
VAXstation 3100 colour monitor cable, 30 inches long.
Specification:
Connectors: 15-way D-type female connector with screw fixings at the system end, and a connector block with 3 BNC co-axial connectors each attcahed via a short lead on the monitor end.
Each BNC connector has a 'R', or 'G', or 'B' embossed legend to indicate correct connection.
Typical Usage: To connect the monitor to a VAXstation 3100 Colour model (including SPX option), or to a DECstation 3100 Colour model.
Ordering Information:
BC23J-03 p/n 17-01992-01
BC23P
Description A ten foot "Octopus" cable assembly to convert 8 DECconnect Modified Modular Jack (MMJ) outputs to one 36-way connection suitable for connection to an H3104 Cable Concentrator.
Specification Unshielded.
Number Of Conductors 36 (18 twisted pairs) on single cable part, 6 on each MMP terminated cable part.
Connectors 8 Modified Modular Plugs (MMPs) on one end of the cable, each one being numbered, and one 36-way centronics style connector on the other end.
Typical Usage For use with the DECserver 300. The use of two BC23P cables enables two H3104s to be connected to a DECserver 300 for the purpose of patching in a Satellite Equipment Room. N.B. : As this "octopus" cable has only 36 conductors, it is NOT suitable for customers wishing to utilise the DTR/DSR facilities offered by the DECserver 300, it can accommodate only the transmit and receive data.
Ordering Information E0-BC23P-10.
Two of these cables are needed for each DECserver 300, and they need to be ordered as an optional extra.
Description Internal 8-bit SCSI cable used on the AlphaServer 2100 systems to connect a narrow, or 8 bit, SCSI controller to the internal storage shelf. This is a ribbon cable approximately 1.2m long, with a large ferrite bead at the halfway point.
Connectors Two 50-way, female, keyed IDC Ribbon Cable Connector sockets (Berg connectors) crimped onto a 50-conductor flat , ribbon cable.
Ordering Information BC25R-3B (17-03948-01)
BC25T
Description Internal 16-bit SCSI cable used on the AlphaServer 2100 systems to connect a wide, or 16-bit, SCSI controller to the internal storage shelf. This is a ribbon cable approximately 1.2m long, with a large ferrite bead at the halfway point.
Connectors Two 68-way, male, IDC ribbon cable connectors crimped onto a flat ribbon cable.
Ordering Information BC25T-3L (17-04180-01)
Description
Internal 16-bit SCSI cable used on AlphaServer 2000 systems to connect a wide, or 16-bit, SCSI controller to the internal storage shelf. This is a ribbon cable approximately 0.8m long.
Connectors Two 68-way, male, IDC ribbon cable connectors crimped onto a flat ribbon cable.
Ordering Information BC25U-2H (17-04088-01)
BC27A
Description This cable is designed to connect a line printer to any Data Products protocol parallel port other than the LPV11-SA
Specification Shielded.
Number Of Conductors 25
Connectors 37-pin male D-type at controller end, 50-pin male D-type at printer end.
Wiring
50-Pin End (Printer) Signal 37-Pin End (Controller) 19 Data Bit 1 26 3/35 Return 30 20 Data Bit 2 20 4/42 Return 34 1 Data Bit 3 22 2/14 Return 28 41 Data Bit 4 1 40 Return 33 34 Data Bit 5 24 18/37 Return 35 43 Data Bit 6 23 42 Return 34 36 Data Bit 7 5 35 Return 30 30/28 Paper Instruction 6 23 Demand 18 7/40 Return 33 38 Data Strobe 8 37 Return 35 21 On Line 12 5/45 Return 32 46 Interface Verify 14 45 Return 32 26 VFU Ready 17 10 Return 31
Typical Usage Connects the LP11, LPV11, DMB32 DECserver 250, parallel controller ports to LP25, LP26, LP27, LP29, LP37, LG01, and LG02. Use the BC27L cable when connecting a line printer to an LPV11-SA (BA200 series cabinet dual port) controller.When connecting a line printer directly to an LP11 module, ie to the actual printed circuit board, use the 70-16560-30 cable.
Ordering Information BC27A-30, BC27A-50.
Description: Monochrome monitor cable, 3 feet long.
Specification:
Connectors: D-type connector with 3 co-axial sockets, with fixing screws at the system end, and a BNC co-axial connector at the monitor end.
Typical Usage: To connect the monitor to the monochrome DECstation 5000 models 20, 25, 33.
Ordering Information:
BC29M-03
p/n 17-03399-01
Description Cable designed to connect a Datapoducts interface line printer to a RapidPrint 200 Universal Network Printer Interface.
Specification
Connectors: Connector 1 - 25-way, male, D-type at the RapidPrint end, Connector 2 - 50-way, male, D-type at the printer end.
Typical Usage To connect the Dataproduct interface of a printer such as the LG06 or the LG12 to a network via the Rapidprint 200 (DSTPP-AE).
Ordering Information BC27Z-10, BC27Z-30 (17-04148-01, 17-04148-02).
BC29G
Description: Triax colour monitor cable 9 feet in length.
Specification:
Number of Conductors: 3.
Connectors: D-type connector with 3 co-axial sockets, with fixing screws at the system end, and 3 BNC co-axial connectors on short leads to a connector block at the colour monitor end. The short leads at the monitor ends are coloured red, or green, or blue.
Typical Usage: To connect the colour monitor to the following systems:
VAXstation 4000 model VLC (except VRT13 based system)
VAXstation 4000 models 60 and 90.
DECstation 5000 models 100 and 200 series colour models.
Ordering Information:
BC29G-09
p/n 17-02906-01
The BC29G-09 is a 9 feet long version of the BC29H-2E1 E="bc2ormation
Order from BIEN Data (Se cable.
BC29H
Description: Triax colour monitor cable with an overall length of 3 feet.
Specification:
Number of Conductors: 3
Connectors: D-type connector with 3 co-axial sockets, with fixing screws at the system end, and 3 BNC co-axial connectors on short leads to a connector block at the colour monitor end.
The short leads at the monitor ends are coloured red, or green, or blue.
Typical Usage: To connect the colour monitor to the Personal DECstation 5000 models 20, 33, and 125.
Ordering Information:
BC29H-2E
p/n 17-02906-02
The BC29H-2E is a 3 feet long version of the BC29G-09 cable.
Description: Modem cable to connect the 9-way, male, serial port of a PC to the 25-way, female, port of an RS232 Modem.
Specification:
Number of Conductors 9.
Connectors: One 9-way D-type female, one 25-way D-type male.
Wiring: Straight-through.
Pin Pin Signal 1 8 DCD Received Line Signal Detect 2 3 Rx Received Data 3 2 Tx Transmitted Data 4 20 DTR Data Terminal Ready 5 7 SIG GND Signal Ground 6 6 DSR Data Set Ready (DCE Ready) 7 4 RTS Request To Send (Ready For Receiving) 8 5 CTS Clear To Send 9 22 RI Ring Indicator
Typical Usage:
1. To connect a PC to a modem.
2. To connect the 9-way OBM (Out-Of Band Management) serial port of the DEChub 900 MultiSwitch, and also the OBM port of the DEChub One docking station, to a modem.
Ordering Information:
BC29P-10.
p/n 17-03860-01.
This cable is available from
BIEN Data, Crowmarsh Gifford, Oxfordshire.
Tel 0491-826030
Description: Null Modem cable to connect to the 9-way, male, serial port of a PC.
Specification:
Number of Conductors 9.
Connectors: Two 9-way D-type female connectors.
Wiring: Null Modem (crossed).
Pin Signal Pin Signal 1 DCD Received Line Signal Detect 4 DTR 2 Rx Received Data 3 Tx 3 Tx Transmitted Data 2 Rx 4 DTR Data Terminal Ready 1 DCD 5 SIG GND Signal Ground 5 Sig Gnd 6 DSR Data Set Ready (DCE Ready) 4 DTR 7 RTS Request To Send (Ready For Receiving) 8 CTS 8 CTS Clear To Send 7 RTS 9 RI Ring Indicator Not connected
Typical Usage: To connect a PC to the 9-way OBM (Out-Of Band Management) serial port of the DEChub 900 MultiSwitch, and also the OBM port of the DEChub One docking station.
Ordering Information:
BC29Q-10.
p/n 17-03861-01.
This cable may also be available from BIEN Data, Crowmarsh Gifford, Oxfordshire.
Tel 0491-826030
Description: DSSI cable to connect the VAX/DEC 4000 system to the HSD05 or HSD30 DSSI to SCSI adapter/controller.
Specification:
Connectors: One 50-way MR (micro-ribbon) right-angled connector for the HSD, and one 50-way PS (pin socket or tab) right-angled connector for the system end.
Ordering Information:
BC29R-06, -09, -16, -30, 45, -60.
p/n 17-03855-04, -05, -06, -07, -08, -09.
Description DSSI cable to connect the VAX/DEC 6000/7000/10000 system to the HSD05 or HSD30 DSSI to SCSI adapter/controller.
Specification:
Connectors: One 50-way MR (micro-ribbon) right-angled connector for the HSD, and one 50-way MR straight connector for the system end.
Ordering Information
BC29S-06, -09, -16, -30, 45, -60.
p/n 17-03855-01, -02, -03, -10, -11, -12.
Description DSSI cable to interconnect two DSSI nodes, such as HSD05s, from a horizontal shelf to a vertical shelf on the same side of a StorageWorks Data Centre cabinet.
Specification:
Connectors: Two 50-way MR (micro-ribbon) right-angled connectors. Both connectors are right-angled in the same direction.
Ordering Information
BC29T-03, -09.
p/n 17-03855-13, -14.
Description DSSI cable to interconnect two DSSI nodes, such as HSD05s, which are housed on adjacent horizontal shelves on the same side of a StorageWorks Data Centre cabinet.
Specification:
Connectors Two 50-way MR (micro-ribbon) right-angled connectors. One connector is right-angled to the right, the other to the left.
Ordering Information:
BC29U-02.
p/n 17-03855-15
Description Link cable for HSD 10/30 Adapters/Controllers
Specification:
Connectors: Two MR (micro-ribbon) type, right-angled connectors.
Typical Usage:
Ordering Information:
BC29V-01
p/n 17-03855-17
BC42A
Description 30 inch long power convenience or jumper cable used to "daisy-chain" AC power from one option to another in a tidy manner.
Specification
Number Of Conductors Three.
Connectors IEC plug at one end, IEC socket at the other.
Ordering Information BC42A-29 (17-00365-19)
Description Extension cable for both EIA-422 and 423.
Specification
Number Of Conductors 37, 18 twisted pairs plus one single conductor.
Connectors One 37-way D-type male, one 37-way D-type female.
Wiring Straight through.
Typical Usage To extend either the BC19B (EIA-422), or the BC19E (EIA-423) adapter cables when used with synchronous controllers.
Ordering Information
BC55D-25, -50.
BC56H
Description Single-ended SCSI cable.
Connectors One 68-way, high-density, Honda, female, straight connector with cut-out locating keys; one 50-way low-density, Centronics style, straight connector.
Typical Usage To connect the first SCSI device to an InfoServer 150.
Ordering Information
E0-BC56H-03, -06, -09 (feet)
(17-02008-01, -02, -04).
The BC56H-03 and the BC19J-1E are generally shipped with non-embedded SCSI options.
Description Modem cables specifically designed for the PC product family, and may also be used as a printer cable for the Rainbow PC. The BCC04 is very similar to 1 E="bc2ormation
Order from BIEN Data (Se cable.
the BC22F, and the BCC14 is very similar to the BC22E.
Specification Gauge: 26-AWG
Number Of Conductors 25 for BCC04, 16 for BCC14.
Connectors One male, and one female 25-way D-type. These connectors, unlike the BC22E/F cables have screw fastenings through the mouldings.
Wiring Pin to pin.
BCC04 - all pins are connected.
BCC14 - only pins 1, 2, 3, 4, 5, 6, 7, 8, 12, 15, 17, 19, 20, 22, 23, 24.
Typical Usage Modem connection to PCs fitted with a 25-way serial port, or, a printer connection to a DEC Rainbow.
Ordering Information
BCC04-10, E0-BCC04-25, E0-BCC04-50. E0-BCC14-10.
Description A printer cable designed for connecting printers to the DECmate and Professional PCs and the VT200 series terminals. Not suitable for the Rainbow PC which uses the BCC14 cable.
Specification Gauge: 26-AWG
Number Of Conductors 7
Connectors One 25-way female D-type (printer end), one 9-way female D-type (PC end), with screw fasteners.
Wiring Null Modem.
9-Way End 25-Way End Ground 1 1 Ground Tx 2 3 Rx Rx 3 2 Tx RTS 4 5 CTS DTR 5 6 DSR DSR 6 20 DTR Signal Ground 7 7 Signal Ground
Ordering Information
EO-BCC05-10, -25, -50.
BCC27
Description: VRT13 monitor cable, 5 feet long
Specification:
Connectors: 9-way D-type, male connector with fixing screws and 15-way D-type, male connector with fixing screws.
Typical Usage: To connect a VRT13 monitor to a VAXstation 4000 VLC. Also used with VRT13 based PCs.
Ordering Information:
BCC27-05
p/n 30-34762-03
BCC45
Description Five feet long keyboard extension cable suitable for the following keyboards :
LK450-AA, PCXAL-xx, and LK250-PA.
Specification
Connectors One 6-way mini-DIN male (PS/2 style), one 6-way mini-DIN female.
Ordering Information
BCC45-06.
Description 2.5m, power cable with special connector. For UK use.
Specification
Connectors One straight IEC320 C15 socket with keyed cutout, one UK 240v plug.
Typical Usage Alpha 3000-500, DECNIS.
Ordering Information
BN12A-2E (17-00209-03).
BN18B
Description 4.5m, power cable with straight connector. For UK use.
Specification
Connectors One straight IEC320 C19 sockey, one UK 240v plug.
Typical Usage HSC65, HSC95.
Ordering Information
BN18B-4E (17-00209-05).
BN19A
Description Grey, 2.5m, power cable with right-angled connector. For UK use.
Connectors Connector 1 - Straight IEC320 C13 socket. Connector 2 - UK 240v plug.
Typical Usage General purpose.
Note: The BN19A-2E is interchangeable with the BN26D-2E. The BN26D-2E is coloured black, whereas the BN19A-2E is grey.
Ordering Information
BN19A-2E (17-00209-15).
BN19B
Description Grey, 2.5m, power cable with right-angled connector. For UK use.
Connectors One right-angled IEC320 C13 socket, one UK 240v plug.
Typical Usage General purpose.
Ordering Information
BN19B-2E (17-00209-18).
BN20E
Description Black, 2.5m, power cable with right-angled connector, for UK use.
Connectors One right-angled IEC320 C15 socket with shoulder, one UK 240v plug.
Typical Usage LANbridge 150, LANbridge 200, DECrepeater 200.
Ordering Information
E0-BN20E-2E (17-00209-04).
BN21H
Description: SCSI cable used for 8-bit single-ended communications. 8-bit single-ended SCSI cables are also known as "A" cables.
Connectors Two 50-way high density Honda male, straight, with thumb latches.
Typical Usage
1. To interconnect adjacent BA350 shelves.
2. To daisy-chain BA353 Desktop Expansion boxes.
3. To connect the HSJ40 shelf to an SBB shelf in a data centre cabinet.
4. To connect BA350 shelves to certain host systems.
5. To connect HSC9X-SX HSC SCSI Data Channels, via the bulkhead I/O panel to a BA350 shelf within that HSC cabinet.
Ordering Information
BN21H-0C (0.3m), BN21H-0E (0.5m), BN21H-01, BN21H-1E (1.5m), BN21H-02, BN21H-03, BN21H-05.
(17-03566-18, -09, -16, -17, -15, -10, -11).
BN21J
Description
SCSI cable used for 8-bit single-ended communications. 8-bit single-ended SCSI cable are also known as "A" cables.
Connectors
50-way, high density Honda male right angled connector with screw attachment, and 50-way high density Honda male, straight with thumb latches.
Ordering Information
BN21J-0E (0.5m), BN21J-01, -02, -03, -05.
(17-03566-03, -02, -01, -04, -05).
BN21K
Description
16 bit differential cable
Connectors
Ordering Information BN21K-01, BN21K-02, BN21K-03, BN21K-05, BN21K-10, BN21K-15, BN21K-20 (metres). (17-03565-xx).
BN21L
Description
16-bit differential SCSI cable. Very similar to the BN21K cable (above), except that the BN21L has two right angled connectors. The maximum total length of a differential SCSI bus is 25 metres. 16-bit differential SCSI cables are also known as "P" cables.
Connectors
Two 68-way, high density Honda, male, right angled connectors with jackscrews.
Ordering Information
BN21L-0B (0.15m), -0E (0.5m), -01, -02, -03, -05, -10, -15, -20. (17-03565-xx).
Description Connectors
68-way, high density Honda, male, right angled connector with jackscrews, and
50-way, low density, male, straight with bail locks.
Ordering Information
BN21M-02, -03, -05, -10, -15, -20.
(17-03567-xx).
Description
StorageWorks "Transition" cable. So called because the cable provides a
transition between different connector types.
Connectors
68-way, high density Honda, male, right angled connector with jackscrews, and
50-way, high density, Honda, male, straight with thumb latches.
Ordering Information
BN21N-02, -03, -05, -10, -15, -20 (metres).
(17-03567-xx).
BN21P-0B
Description
SCSI "Y" cable 0.15 metres long. Designed for StorageWorks products to
facilitate configuration.
This "Y" connection cable is used with the 68-pin H879-AA differential
terminator block to allow :
Specification
Connectors
50-way low density, straight connector at the base of the "Y", and 68-way
high density, special, female connectors for each arm of the "Y".
Ordering Information
BN21P-0B (0.15m or 6 inches).
(17-03623-01).
Description
Two metre long adapter cable for connecting VAXstation 3100 Models 38 or 48
which have an 8-bit single-ended SCSI bus, to StorageWorks building block shelf
(BA350). This is a transition cable. So called because it provides a transition
between different connector types.
NOTE : This cable cannot be used in any other configuration or with
any other system.
Specification
Number Of Conductors 38.
Connectors
68-way, high-density, Honda, female, straight, connector without keyed
cut-outs at the VAXstation end, 50-way high density, Honda, male, straight,
connector at the BA350 end.
Ordering Information
BN21P-02 (17-03631-01).
NOTE : The BN21P-02 is dissimilar to the BN21P-0B which is a "Y"
cable.
BN21R
Description
SCSI cable with the correct impedance and internal wiring to meet SCSI-3
specifications which were developed for fast single-ended SCSI.
Although the BC09D cable has the same connector types, its internal wiring
and impedance were designed to SCSI-2 specifications, so the BC09D is not
suitable for use with demanding fast SCSI applications.
Note. Virtually all SCSI cables with a "BC" designation are not wired
to SCSI-3 specifications, whereas virtually all cables made with a "BN"
designation are wired to SCSI-3 specifications.
Connectors One male, 50-way, high-density, straight; and one male
50-way low-density, right-angled.
Ordering Information
BN21R-0E, -01, -02. (17-03742-13, -01, -14)
Description "Y" configuration adapter cable used for = single-ended
SCSI, 0.15 m long.
Connectors 50-way high-density male connector at the base of the "Y",
and a 50-way low-density female connector at each of the two arms of the "Y".
Typical Usage To provide connection to, and SCSI bus I termination
for, a PMAZC Single-ended SCSI K controller mounted in a host system. In this
configuration the BN21V would be connected as' follows: base - to PMAZC module,
arm 1 - to H8574-A Single-ended SCSI Terminator, arm -2perhaps to a BN23G
single-ended, fast SCSI cable which is in turn connected to a BA350 pedestal.
Ordering Information BN21V-0B (17-03821-01)
BN21W
Description "Y" configuration adapter cable used for Fast Wide
Differential SCSI, 0.15 m long. Connectors 68-way high-density male connector at
the base of the "Y", and a 68-way high-density female at each of the two arms of
the "Y".
Typical Usage To provide connection to, and SCSI bus termination for,
a KZPSA Fast Wide Differential SCSI controller module mounted in a host system.
In this configuration the BN21W would be connected as follows: base - to KZPSA
module, arm 1 - to H879 -AA Differential SCSI Terminator, arm 2 - perhaps to a
BN21K Differential SCSI cable connected to a DWZZA-VA in a BA350 pedestal.
Ordering Information BN21W-0B (17-03822-01).
Description "Y" configuration adapter cable used to connect a 16-bit
bus (operating in 8-bit mode) to a 50-way high-density connector.
Connectors 50-way high-density male at the base of the "Y", 68-way
high-density female at each of the two arms of the "Y".
Typical Usage With Sun Microsystems or Hewlett-Packard systems.
Ordering Information BN21X-0B (17-03623-02)
Description "Y" configuration adapter cable.
Connectors 50-way low-density male connector at the base of the "Y",
50-way low-density female connector at each of the two arms.
Typical Usage
Ordering Information BN21Y-0B (17-03829-01)
BN22E
Description
Black, 2.5 m, power cable designed for the VAX 4000 for use in the United
Kingdom.
Specification
Connectors
One right-angled IEC320 C15 socket, one UK 240v plug.
Typical Usage BA400 enclosure.
Ordering Information BN22E-2E (17-00209-13).
Description
SCSI cable with the correct impedance and internal wiring to meet SCSI-3
specifications which were developed for fast single-ended SCSI.
Although the BC09D cable has the same connector types, its internal wiring
and impedance were designed to SCSI-2 specifications, so the BC09D is not
suitable for use with demanding fast SCSI applications.
Note. Virtually all SCSI cables with a "BC" designation are not wired
to SCSI-3 specifications, whereas virtually all cables made with a "BN"
designation are wired to SCSI-3 specifications.
Connectors
One male, 50-way, high-density, straight; and one male 50-way low-density,
straight.
Ordering Information
BN23G-0E, -01, -02.
(17-03742-08, -09, -04)
BN24A
Description
The BN24A-2E daisy-chain connector cable is a 2.5 metre twin conductor
co-axial cable that connects PC/workstations to a daisy-chain faceplate
connector. The cable is terminated at the PC end with a BNC- plug, and at
the,face plate end with a tap plug that fits into the daisy-chain receptacle.
Specification
Minimum bending radius is 1.5 inches.
Number Of Conduct1 > StorageWorks ors
One 5 m co-axial conductor "folded in half" to provide a twin conductor 2.5 m
long with a BNC connector at the "fold", and two connections built into the tap
connector to provide continuity for the two Thinwire daisy chain ends inside the
face-plate. When the BN24A is removed from the face-plate, the contacts inside
the face-plate connector automatically re-make the behind the wall Thin-wire
circuit.
Typical Usage
Connects to the H3114-AA Daisy-Chain In Wall Connector (pack of eight), which
is housed in a European Wall Box 80mm x 100mm, part number H3111-FB- white, and
H3111-FC - grey, (packs of eight), or the international wallbox (80mm x 100mm),
kit of eight (H3111-GB).
NOTE : ONLY eight workstations may be attached to a thin wire
segment when using the "Daisy Chain" system. The maximum length of thin wire
segment cabling behind the wall is 125 meters. The remaining 60 meters of
segment length is reserved for the round trip length of the daisy chain office
cables.
Ordering Information
E0-BN24A-2E, -3E.
BN24B
Description
The FDDI cables consist of dual fibres in a round construction for
flexibility. The FDDI connectors have field-programmable keying, and are
supplied with tethered dust covers.
Specification
Fibre : Dual-window 62.5/125 micron fibre. FDDI products use the 1300 nm
wavelength. The maximum link length for FDDI is 2000m. The connectors meet ANSI,
FDDI, and PMP requirements.
Number Of Fibres 2.
Connectors
Two keyed FDDI Media Interface Connectors (MIC) which are field programmable
for the appropriate type of FDDI connection, (ie. Port A, B, M, or S).
Wiring Cross-over.
Ordering Information E0-BN24B-01, -03, -4E, -10, -20, -30.
BN24D
Description
Consists of a dual fibre of zipcord construction for flexibility. Each cable
is colour coded with red and black connector boots for easy identification of
transmit and receive.
Specification 62.5/125 micron fibre.
Number Of Fibres 2.
Connectors
One FDDI connector, and two colour coded 2.5mm bayonet ST-type connectors.
The black boot indicates the connector is associated with the optical output of
the FDDI equipment, the red, the input.
Wiring Can be cross-over, or non-crossover.
Ordering Information E0-BN24D-01, -03, -4E, -10, -20, -30.
BN24E
Description
A dual fibre cable. The zip-cord joining the two lengths together may be
ripped down to create two separate cables. Each component cable is colour coded
with red and black connector boots for easy identification of transmit and
receive.
Specification
62.5/125 micron fibre. Bandwidth is 160/500 MHz-km 850/1300 mn wavelength.
Minimum bending radius is 1.5 inches.
Number Of Fibres 2.
Connectors Total of four 2.5mm bayonet ST-type connectors.
Wiring
Ordering Information
BN24E-01, -03, -4E, -10, -30.
Description
Used to connect the 8-way MJ (Modular Jack) port of a 10BaseT workstation to
an 8-way MJ faceplate outlet jack. The BN24F is now replaced by the
BN24Q.
Specification
EIA component tested to 20 Mhz. 26 AWG.
Number Of Conductors
Four, ( ie. Two twisted-pairs ).
Connectors
8-Way MP at each end.
Wiring
Cross-over Typical Usage
To connect a PC fitted with a DE101/201 Ethernet controller to an MJ socket
in a wall faceplate.
Use as the office cable for the DECrepeater 350 which does NOT have a
built-in crossover.
Ordering Information BN24F-03, -04, -07.
BN24H
Description
Connects the 6-way MMJ (Modified Modular Jack) port of a terminal or printer
to the 8-way MJ in a faceplate.
Specification
EIA component tested to 20 MHz.
Number Of Conductors
6, in 3 twisted-pairs.
Connectors
One 6-way MMP, one 8-way MP.
Wiring
Cross-over Typical Usage
To connect a DEC423 video terminal or printer to an 8-way MJ wall outlet.
Ordering Information
BN24H-03, -04.
BN24J
Description
Connects the 6-way MMJ port of a DEC423 server to an 8-way MJ patch panel
insert.
Specification
Number Of Conductors
6, in 3 twisted-pairs.
Connectors
One 6-way MMP, one 8-way MP.
Wiring
Pin-To-Pin Typical Usage
To patch a 6-way MMJ port of a DECserver 300 to an 8-way MJ patch panel
insert jack.
Ordering Information
BN24J-01, -03, -07.
BN24K
Description
Connects the 36-way port of a DECserver 200/DL, or a CXA16 terminal server
module to the 50-way port of the H3107-M patch panel insert.
Specification
Shielded
Number Of Conductors
36, in 18 twisted-pairs.
Connectors
One right angle 36-way, and one straight 50-way Centronics style type, male
connector.
Wiring
Typical Usage
Two of these cables would be used to connect a CXA16 terminal server module
to a H3107-M patch panel insert.
Ordering Information
BN24K-03.
BN24L
Description
"Octopus" cable used to connect to the 6-way MMJ ports of a DEC423 terminal
server, to the 50-way port of the H3107-M patch panel insert.
Specificat1 > Storagion
Number Of Conductors
48, in 24 twisted-pairs.
Connectors
One straight, 50-way, male, Centronics style, and eight 6-way MMP connectors
each of which are numbered.
Wiring
Typical Usage
To connect the MMJ ports of a DECserver 300 to the H3107-M patch panel
insert.
Ordering Information
BN24L-03 (17-02920-01).
BN24N
Description
A one-to-eight "octopus" cable to connect the 36-way port of a DECserver
200/DL, or a CXA16 terminal server module, to the 8-way MJ ports of an H3107-N
patch panel insert. Each of the 8 leads is numbered from 1 to 8.
Specification
Number Of Conductors
24, in 12 twisted-pairs.
Connectors
One right angled, 36-way centronics style, male, and eight 8-way MPs, each
being numbered.
Wiring
Typical Usage
Two of these cables would be used to connect a CXA16 terminal server module,
to an H3107-N patch panel insert.
Ordering Information
BN24N-03 (17-02924-01).
Description Unshielded Twisted Pair cable for either 100BaseT (Fast
Ethernet), 10BaseT (Ethernet) use.
The BN24Q cable replaces the BN24F 10BaseT cable.
Specification Impedance is 100 ohms. Cable is used for 10BaseT,
100BaseTX, and 100Base-T4 applications.
Number of Conductors 8 conductors in 4 twisted pairs. Each conductor
is 24 AWG, stranded.
Connectors 8-way Modular Plug (RJ45) connector at each end of the
cable.
Wiring Crossed. Typical Usage This cable would be used when a cross-over is required,
for instance, when connecting two DE500 Fast Ethernet adapters together, or,
when connecting a DE500 to a DECSWITCH 900 EE/EF (this has no internal
cross-over).
Ordering Information BN24Q-0E, -01, -03, -04, -07.
(P/N 17-04308-01, -02, -03, -04, -05). BN25G
Description
High performance UTP cable used to interconnect two 8-way MJs. May also be
used as an ISDN office cable.
Replaces BN24G.
Category 5 Cable.
Specification
24 AWG stranded conductors.
Number Of Conductors
8, in 4 twisted-pairs.
Connectors
Two 8-way MPs.
Wiring Pin-To-Pin. Typical Usage
Connects a port of a DECrepeater 350 (DETPR), to an H3107-L, or an H3107-N
patch panel. Also interconnects H3107-L and H3107-M, and H3107-L and H3107-N
patch panels. Use as the office cable for the DECrepeater 90T which has bulit in
crossover.
Use this cable where high performance is required.
Ordering Information
BN25G-0E (0.5m), -01, -03, -04, -07.
(17-03212-01, -02, -03, -04, -05).
Description:
UTP (unshielded twisted-pair) cable for use with copper FDDI devices.
Specification:
Unshielded, 100-ohm, Category 5, office cable. 24 AWG.
Number of Conductors:
8 conductors in 4 twisted pairs.
Connectors:
Two 8-way Modular Plugs (RJ45).
Wiring
Crossed. Typical Usage:
Typically to connect two FDDI devices directly, or an FDDI interface card
such to an office faceplate.
Ordering Information:
BN25H-03 (p/n 17-03909-03). BN26M
Description
Shielded cable designed for office or equipment use, to be used with an
active network device such as the DECrepeater 90T which utilizes internal
crossover.
Category 5 cable.
Specification
26AWG stranded conductors.
Number Of Conductors
Eight in four twisted pairs plus shielding.
Connectors
Shielded 8-way MP at each end.
Wiring
Straight through. Typical Usage
Can provide connecting for application such as 802.3/10 base T, 802.5/Token
Ring, and ISDN.
Ordering Information
BN26M-03,04,07.
(17-03194-03, -04, -05).
Description
Shielded office cable designed for 10 Base T repeaters, such as the
DECrepeater 350 which do not incorporate internal crossover.
Specification
Number Of Conductors
Four in two twisted pairs, plus shielding.
Connectors
Shielded 8-way MP at each end.
Wiring
Crossover Typical Usage
Connects a shielded 8-way MJ port of a 10BaseT workstation to the shielded
8-way MJ faceplate outlet jack (H3112-H).
Ordering Information
BN26N-03,04,07.
(17-03195-01, -02, 03).
BN26R
Description
A 50-way to eight 8-way "Octopus" equipment cable used to connect the eight
8-way ports of 10BaseT repeaters or DECserver Terminal Servers to the 50-way
connector of the H3107-M Patch Panel. The BN26R is the direct replacement for
the BN24M cable.
Specification
Number Of Conductors
48 conductors ( 8 x 3 twisted pairs ).
Connectors
One straight, 50-way centronics style male, (plug 9), and eight 8-way MP
(Modular Plug) connectors, (plugs 1-8).
Typical Usage
To connect the eight 8-way MJ ports of the :
....to the H3107-M Patch Panel.
NOTE : The DECrepeater 350 does NOT have a built-in cross-over,
therefore a crossed-over cable (eg. BN24F-xx) would be needed between the office
Face Plate and the device in order to achieve a net cross-over. The DECrepeater
90T DOES have a built-in cross-over, so a straight wired cable (eg. BN26K-xx)
would be needed between the Face Plate and the device.
Ordering In1 > Storagiformation
BN26R-03 (17-03518-01).
Description:
STP (shielded twisted-pair) cable for use with copper FDDI devices.
This cable is the shielded version of the BN25H.
Specification:
Shielded, 100-ohm, Category 5, office cable. 24 AWG.
Number of Conductors:
8 conductors in 4 twisted pairs, plus shield.
Connectors:
Two 8-way Modular Plugs (RJ45) with shields.
Wiring
Crossed. Typical Usage:
Typically to connect two FDDI devices directly, or an FDDI interface card
such to an office faceplate.
Ordering Information:
BN26S-03 (p/n 17-03910-03).
Description:
"Octopus" cable to adapt a 50-way Telco socket on a 10BaseT repeater to
twelve individual RJ45 plugs.
Specification:
Number of Conductors:
Total number of conductors is 48 (24 twisted pairs). There are 4 conductors
at each of the 12 RJ45 plugs.
Connectors:
One 50-way Telco connector, and twelve 8-way RJ45 plugs (MPs, or Modular
Plugs).
Wiring:
The pin/signal assignment at the RJ45 connector is : Typical Usage:
To connect one of the two 50-way Telco sockets on the DECrepeater 900GM to a
patch panel.
Ordering Information:
BN26U-03 (p/n 17-03912-01)
Description
General purpose SCSI cable
Specification
Connectors:
Typical Usage
To connect a SCSI device to a BA364 or BA362 Storage enclosure which requires
a straight entry 68-eay cable.
Ordering Information: BN31G-01, -1E, -02 (p/n 17-03916-03, -10,
-01). BN31K
Description Internal cable and bulkhead plate with socket designed to
present the third SCSI channel of a KZPSC PCI RAID controller to a socket at the
I/O panel of a pedestal AlphaServer 2000/2100. Cable is 0.5m long.
Connectors 68-way, male, right-angled IDC ribbon cable connector at
the KZPSC module end, connected via a flat ribbon cable to a bulkhead assembly
consisting of a 68-way, very-high-density (0.8mm pitch) female connector set
into a mounting plate suitable for fixing into a convenient I/O slot.
Typical Usage To enable the connection of an external StorageWorks
storage pedestal to the third SCSI channel of the KZPSC controller as follows:
8-bit SCSI pedestal, eg, BA350-KF --- use BN31L-1E external cable, 16-bit SCSI
pedestal, eg BA356-KB (BUS 1) --- use BN31S-1E, 16-bit SCSI pedestal, eg
BA356-KB (BUS 2) --- use BN31M-1E.
Ordering Information BN31K-0E (17-04108-01)
BN31L
Description Cable designed to connect an external port of the KZPSC
RAID controller to an 8-bit StorageWorks a pedestal. Cable length is 1.5 m.
Connectors 68-way, male, straight, 0.8mm pitch - very high density -
connector withK thumb screws (this looks like a sub-miniature Centronics style
connector at the KZPSC RAID controller end, and a 50-way high-density, male,
straight connector at the StorageWorks enclosure end.
Typical Usage To connect a KZPSC PCI RAID controller's external port
to an external BA350-KF pedestal. The KZPSC-BA directly presents two VHD 68-way
ports at the bulkhead for two of its SCSI busses, if its third SCSI bus was
required for external use then a BN31K-0E Internal Cable/Bulkhead Assembly would
need to be installed.
Ordering Information BN31L-1E (17-04107-01).
Description Cable designed to connect an external port of the KZPSC
RAID controller to an 16-bit StorageWorks a pedestal. Cable length is 1.5 m.
Connectors 68-way, male, straight, 0.8mm pitch - very high density -
connector with thumb screws (this looks like a sub-miniature Centronics style
connector) at the KZPSC RAID controller end, and a 68-way high-density, male,
straight connector at the StorageWorks enclosure end.
Typical Usage To connect a KZPSC PCI RAID controller's external port
to an external BA356 pedestal. The BN31M cable would be selected when connecting
to BUS 2 (Output) at the BA356's Personality Module. The similar BN31S would be
used for BUS 1 connection. The KZPSC-BA directly presents two VHD 68-way ports
at the bulkhead for two of its SCSI busses, if its third SCSI bus was required
for external use then a BN31K-0E Internal Cable/Bulkhead Assembly would need to
be installed.
Ordering Information BN31M-1E (17-04107-02)
Description Cable designed to connect an external port of the KZPSC
RAID controller to an 16-bit StorageWorks a pedestal. Cable length is 1.5 m.
Connectors 68-way, male, straight, 0.8mm pitch - very high density -
connector with thumb screws, (this looks like a sub-miniature Centronics style
connector) at the KZPSC RAID controller end, and a 68-way high-density, male,
right-angled connector at the StorageWorks enclosure end.
Typical Usage To connect a KZPSC PCI RAID controller's external port
to an external BA356 pedestal. The BN31S cable would be selected when connecting
to BUS 1 (Input) at the BA356's Personality Module. The similar BN31M would be
used for BUS 2 connection. The KZPSC-BA directly presents two VHD 68-way ports
at the bulkhead for two of its SCSI busses, if its third SCSI bus was required
for external use then a BN31K-0E Internal Cable/Bulkhead Assembly would need to
be installed.
Ordering Information BN31S-1E (17-04107-03)
Description
General purpose fast SCSI cable. 1 m long. This cable is functionally the
same as FR-PCXAR-WK (p/n 17-04154-01)
Specification
Connectors
Typical Usage
To connect a SCSI device to a BA364 or BA362 Storage enclosure which requires
a straight entry 68-way cable.
Ordering Information: BN31V-01 (p/n 17-03567-24) General purpose fast SCSI cable. 1 m long. This cable is functionally the
same as FR-PCXAR-WL (p/n 17-04154-02)
Specification
Connectors
Typical Usage
To connect a SCSI device to a BA364 or BA362 Storage enclosure which requires
a straight entry 68-way cable.
Ordering Information: BN31W-01 (p/n 17-03567-21) Description Fibre Optic cable of zipcord construction with ST
push-pull connectors on one end, and SC connectors on the other.
Specification
Number of Conductors Dual 62.5/125-micron multi-mode fibre conductors.
Connector1 > Storas Two SC connectors on one end, and two ST
push-pull connectors on the other. The connectors at each end of the cable have
a Red and Black boot to identify the Transmit and Receive signal path.
Typical Usage
Ordering Information BN34A-01, -2E, 03, -4E, -10, -20, -30
(17-04147-01, -02, -03, -04, -05, -06, -07)
BN34B
Description Fibre Optic cable of zipcord construction with SC at each
end.
Specification
Number of Conductors Dual 62.5/125-micron multi-mode fibre conductors.
Connectors Two SC connectors at each end of the cable.
Typical Usage
Ordering Information BN34B-01, -2E, 03, -4E, -10, -20, -30
(17-04138-01, -02, -03, -04, -05, -06, -07)
Description Fibre Optic cable of zipcord construction with ST
push-pull connectors at each end. The push-pull construction provides easy
insertion and high repeatability.
Specification
Number of Conductors Dual 62.5/125-micron multi-mode fibre conductors.
Connectors Two ST push-pull connectors at each end of the cable.
Typical Usage
Ordering Information BN34C-01, -2E, 03, -4E, -10, -20, -30
(17-04145-01, -02, -03, -04, -05, -06, -07)
Description Fibre Optic cable of zipcord construction with SC
connectors on one end, and an MIC onnector on the other.
Number of Conductors Dual 62.5/125-micron multi-mode fibre conductors.
Connectors Two SC connectors on one end, and an MIC (FDDI Media
Interface Connector) on the other. The connectors at the SC end of the cable
have a Red and Black boot to identify the Transmit and Receive signal path. The
MIC connector is keyed and is field programmable for the appropriate type of
FDDI connection.
Typical Usage
Ordering Information BN34D-01, -03, -10. (17-04185-01, -03, -05)
Description SCSI adapter cable with built-in 9-bit termination
designed to allow the correct connection of a narrow (8-bit) SCSI device to a
wide (16-bit) SCSI workstation. This adapter cable is 0.16 metres (6 inches)
long.
Specification
Connectors
Typical Usage To connect a narrow SCSI device such as a TLZ07 to the
68-way SCSI connector on the AlphaStation 500. The 68-way connector would be
connected to the AlphaStation and would terminate the high-byte; the 50-way
connector would be joined to the high density 50-way end of a cable such as the
BN23G, and the other 50-way low-density end of the BN23G would connect to the
TLZ07 tape drive.
Note that this BN36A-0B adapter is not needed when connecting devices
designed for use with the newest AlphaStations, as these devices, such as the
appropriate TLZ09 option have a built-in adapter.
Ordering Information BN36A-0B (17-04401-01)
Description Cable which connects to one of the 68-way connectors of
the DECserver900GM, and then presents four separate DB25 connectors, each with
EIA-232 data and full modem control signals. Cable is 3 metres in length.
Specification
Connectors Connector 1 - 68-way male, right-angled, Amplimite
D-subminiature, Connectors 2,3,4,5 - 25-way, male, D-type.
Wiring Pin/Signal Designation for the DB25 connectors. Typical Usage The DB25 connectors would typically be connected to the
port of an EIA-232 Modem requiring full control signals.
Ordering Information BN41A-03 (17-03973-01).
Description Cable which connects to one of the 68-way ports of the
DECserver900GM, and then presents eight sets of data and partial modem control
signals on eight separate MP8 connectors. Cable is 3 metres in length.
Specification
Connectors Connector 1 - 68-way male, right-angled, Amplimite D-sub
miniature, Connectors 2,3,4,5,6,7,8,9 - 8-way, Modular Plug.
Wiring Pin/Signal Designation for the MP8 connectors.
Pin Signal Typical Usage The MP8 connectors would typically be used with an
H8585-AC MJ8 to DB25 adapter at the port of EIA-232 Modem.
Ordering Information BN41B-03 (17-03974-01).
Description Cable which converts one of the 68-way ports of the
DECserver900GM to a 50-way Telco connector. Eight sets (DL1-8) of signals will
then be available at the Telco for subsequent distribution at an Open DECconnect
Patch Panel. Cable is 3 metres in length.
Specification
Connectors Connector 1 - 68-way male, right-angled, Amplimite D-sub
miniature, Connector 2 - 50-way Telco connector.
Wiring Typical Usage The 50-way Telco connector would be typically connected
into an H3117-MA Snap-in 50-way to 8 x 8MPJ Patch Panel Insert for the H3108
series Patch Panel Frame.
Ordering Information BN41C-03 (17-03972-01).
Description Cable which connects to one of the 68-way ports of a
DECserver900GM and then presents eight sets of EIA-232 signals with partial
modem controls (DL1-8) on eight different DB25 connectors. Cable is 3 metres in
length.
Specification
Connectors Connector 1 - 68-way male, right-angled, Amplimite D-sub
miniature, Connectors 2,3,4,5,6,7,8,9 - 25-way D-type male.
Wiring Pin/Signal designation for the 25-way connectors. Typical Usage This cable is designed for the Netrider 900 package.
Ordering Information BN41D-03 (17-04214-01).
Description
The BNCIA cable set is designed as the interface cable for Digital's 70Mbits
dual path Computer Interconnect (CI). There are four cables in the set; Transmit
and Receive for the A path, and Transmit and Receive for the B path.
Specification
Gauge is 0.410 inch diameter cable. Double braid and foil shields.
Number Of Conductors
Four separate co-axial cables.
Connectors
TNC type connectors at all ends.
Typical Usage
To connect VAXcluster nodes to the passive SC008 Star Coupler "hub". The
capacity of the CI is 16 nodes, and the maximum separation between two nodes is
90m.
NOTE:
A Star Coupler must always be used, even for only two nodes, (eg. connecting
an HSC70 to a CIBCA), since the CI receivers are designed to accept only the
highly attenuated signals which are offered by the SC008 which must be able to
passively transmit signals to up to 16 nodes. Use the SC008-AC for up to 8
nodes, and the SC008-AD for between 9 and 16 nodes.
Ordering Information
E0-BNCIA-10, -20, -45.
Description
The BNE2A (Teflon insulation), and the BNE2B (PVC), is the cable used for
base-band 10 Mb/s Ethernet. Transceiver placements are marked on the cable every
2.5m. Maximum length of a BNE2A/B segment is 500m.
Specifications
IEEE 802.3, 10 Base 5, Beldon 9880. Gauge: 11.5 AWG, Impedance: 50 ohms.
Minimum bending radius: 20 cm (8 inches). Diameter: 1.0 cm.
Number Of Conductors
One co-axial conductor.
Connectors
"N" male co-axial connectors both ends.
Hardware
50 Ohm Impedance Terminator to correctly terminate an Ethernet segment - P/N
12-19816-01.
Barrel connector to join two lengths of Ethernet cable together - P/N
12-19817-01.
Loose end connectors to crimp onto unterminated cable - P/N 12-19118-00,
using the H3 Crimping Tool P/N 29-24662-00.
Ordering Information
E0-BNE2A/B-MA (23.4m),
E0-BNE2A/2B-MB (70.2m),
E0-BNE2A/B-MC (117m),
E0-BNE2B-ME (500m).
BNE4C
BNE4G
Description
These are Ethernet Transceiver cables which are fully IEEE 802.3 compliant.
The maximum length for a transceiver cable is 50m.
BNE3x cables are low loss, whereas BNE4x cables are higher loss but are
thinner and are more suitable for office use.
BNExC, BNExD, BNExH, BNExK are PVC insulated.
BNExL, BNExM are Teflon insulated.
BNExD, BNExK, BNExM have right angled connectors.
BNExC, BNExH, BNExL have straight connectors.
Specification
For Low Loss:
Gauge: 20-AWG, impedance: 78 ohms.
Minimum bending radius: 10 cm.
Diameter: 1.3 cm.
For Office:
Minimum bending radius: 10 cm.
Diameter: 0.6 cm.
Number Of Conductors
8 (four twisted pairs), plus drain wire. Each TWP is screened with foil. The
cable is screened with both foil and braid.
Connectors
One male (device end), one female (transceiver end), 15-way D-type connectors
with slide latch for easy connection.
Wiring
Pin to pin. Typical Usage
To connect Ethernet devices to the Ethernet via H4005 Transceivers or DELNIs.
Only Teflon cables should be used in an environmental airspace.
Use the BNE4G-02 for connection to EtherWORKS cards with an AUI port.
The BNE4G-02 is available only in this 2m length. Customers who require a
longer cable may add a standard transceiver cable to it it, to achieve the
required length.
Ordering information
Straight Connectors Right-Angle Connectors BNE4G-02
Note : The BNE4G-02 has screw fittings at the PC (male) end, and the normal
slide latch at the transceiver (female) end.
BS19D
Description
The BS19D is the EIA-232 synchronous adapter cable kit consisting of the
BC19D-02 V.24 cable, an EIA-232 adapter connector part number 12-27591-01, and
an information sheet EK-BS19D-IS.
Specification
Number Of Conductors
16 conductors in the BC19D cable, 13 in the 12-27591-01 EIA-232 adapter
connector.
Connectors
The cable kit has one 25-way male D-type, and one 50-way female D-type
connector.The adapter connector has one male and one female 25-way D-type
connector; the female end is to connect to the male 25-way connector of the
BC19D cable.
Wiring
Pins 2,3,4,5,6,7,8,15,17,20,22,24,25 on the EIA-232 adapter connector are
connected pin to pin, no other pins are connected.
Typical Usage
To adapt the standard 50 pin synchronous output connector to BTs low speed
(9.6Kb/s) Kilostream.
Use the BC22F to extend the BS19D adapter.
Ordering Information
E0-BS19D-02.
Description
A synchronous adapter cable kit to adapt Digital's standard 50-way
synchronous connector to V.24 / V.28. This cable is very similar to the BS19D-02
adapter cable, but includes SMI (Speed Mode Indication). The kit includes a
BC23V-02 cable, plus a 12-27591-01 adapter.
Specification
Number Of Conductors
Connectors
The BC23V-02 cable has one 50-way female, and one 25-way male D-type
connector. The adapter ( P/N 12-27591-01) has one male, and one female 25-way
connector.
Wiring Typical Usage
To adapt Digital's 50-way synchronous output connector for V.24 /V.28 use.
Ordering Information
E0-BS23V-02
Description
Flat terminal interconnection cable with PVC insulation. For low speed
applications only.
Specification
26 AWG, stranded conductors.
Number Of Conductors
6 conductors in a flat jacket.
Connectors
H8220 - 6-way MMP (Modified Modular Plugs) in a pack of 50, may be crimped
with the H8241 Crimp Tool, onto a desired length of H8240 cable to make "BC16E"
terminal or printer cables. Such a cable would require a cross-over connection.
Typical Usage
For office use only; not for use in building wiring.
Supports EIA-232, and EIA-423.
Ordering Information
H8240 1,000ft (305m) reel.
(17-00721-01).
Description
The H8240-A is an EIA/TIA Category 5, high-performance, data grade,
unshielded twisted-pair cable. PVC insulated.
Specification
100 Ohm impedance, 24 AWG, stranded conductors.
Category 5.
Number Of Conductors
8 conductors in 4 twisted pairs.
Connectors
May be terminated with the H8226-AA 8-way modular plugs ( pack of 50 ), using
the H8100-G crimp tool, or the H8241 crimp tool with the H8100-F die set.
Typical Usage
Can be used to make custom cables for applications that require high speed
data transmission. For office use only: not for use in building wiring
Ordering Information
H8240-A is a 305m ( 1,000ft ) reel of cable (17-03167-01)
Description
The H8240-B is an EIA/TIA Category 5, high-performance, data grade, shielded
twisted-pair cable. PVC insulated.
Specification
100 Ohm, 26 AWG stranded conductors.
Number Of Conductors
8 conductors in 4 twisted-pairs plus shield.
Connectors
May be terminated with the H8226-AB 8-way shielded modular plugs (pack of 50
), using the H8100-G crimp tool, or the H8241 crimp tool with the H8100-F die
set.
Typical Usage
Can be used to make custom cables for applications that require high speed
data transmission. For office use only: not for use in building wiring.
Ordering Information
H8240-B is a 305m ( 1,000ft ) reel of cable (17-03169-01)
Description
The H8245-A UTP (Unshielded Twisted Pair) cable is a category 3, standard
data grade cable, jacketed with PVC. The H8246-A cable is jacketed with Teflon.
These cable feature excellent pair-to-pair near-end cross talk levels.
Specification
24 AWG, solid conductors, 100 Ohm.
Category 3.
Diameter of PVC cable is 0.48cm, diameter of teflon cable is 0.43cm.
Minimum bending radius is 2.54cm
Number Of Conductors 8 conductors in 4 pairs.
Typical Usage
For DEC423, maximum distances are :
For 10BaseT :
If it is required to terminate this cable with 6-way MMPs (Modified Modular
Plugs), use the H8226-00 (50 pack) connectors, and the H8241 Crimp Tool.
Ordering Information
H8245-A, 1,000 feet reel (17-01313-01).
H8246-A, 1,000 feet reel (17-01286-00).
Description
The H8245-C UTP (Unshielded Twisted Pair) cable is a Category 5, high-speed,
high-performance cable, jacketed with flame-retardant polyethylene. The H8246-C
cable is jacketed with Teflon. These cables feature excellent pair-to-pair
near-end cross talk levels.
Specification
24 AWG, solid conductors, 100 Ohm.
Category 5.
Number Of Conductors
8 conductors in 4 pairs.
Typical Usage
These cables support high-speed applications including 16Mb/s Token Ring at
lobe lengths of 100m wit 18 DSR 6 57 43 DTR 6 25 hout signal amplifiers.
Ordering Information
H8245-C 1,000 feet reel. (17-03030-01)
H8246-C 1,000 feet reel. (17-03029-01).
Description
The H8245-D STP (Shielded Twisted Pair) cable is a Category 5
high-performance cable jacketed with flame-retardant polyethylene. The H8246-D
cable is jacketed with Teflon. These cables feature excellent pair-to-pair
near-end cross-talk levels.
Specification
24 AWG, solid conductors, 100 Ohm.
Category 5.
Number Of Conductors
8 conductors in 4 pairs, plus shielding.
Typical Usage
These cables support high-speed applications including 16Mb/s Token Ring at
lobe lengths of 100m without signal amplifiers.
Ordering Information
H8245-D 1,000 feet reel (17-03170-01)
H8246-D 1,000 feet reel (17-03171-01).
H0401 Crossover Switch
Description
The H8571/H8575 E1A-423 to EIA-232 series passive adapters adapt 25-way and
9-way D-type sub-miniature connectors to Modified Modular Jacks (MMJ).
H8575-A
MMJ to 25-way, female, filtered D-type with jack screws for mating to a
device's (male) connector.
Wiring: Straight through.
H8575-B
MMJ to 9-way, female, filtered D-type with jack screws for mating to the
9-way (male) printer port of an early Digital terminal. Virtually obsolete.
Wiring: Straight through
H8571-C
MMJ to 25-way, male, unfiltered D-type with mounting nuts for securing to
cables such as the BC22D which has female connectors.
Wiring: Crossed.
H8575-D
MMJ to 25-way, male, filtered D-type with jack screws for connection to the
printer port (female) of the Rainbow (PC100) Personal Computer.
Wiring: Crossed
H8575-E
MMJ to 25-way, male, filtered D-type with jack screws for connection to LJ250
colour printers. Also suitable for adapting printers which are non-Digital, and
have a female port.
Wiring: Straight through.
H8571-J
MMJ to 9-way, female, D-type with jack screws for mating to PC style 9-pin
(male) port. This adapter conforms to EIA-574.
Wiring: Straight through.
NOTE: The pin/signal designation is different to the H8575-B.
Where "Crossed" indicates the EIA-232 Transmit Data is connected to the
DEC-423 Receive Data, and vice versa, and similarly with DTR and DSR. See also
Appendix B.
Ordering Information
E0-H8575-A
E0-H8575-B
H8571-C
H8575-D
H8575-E
E0-H8571-J
Here are some pictures of the adapters. The first picture shows,
anti-clockwise from bottom left, H8575-A, H8575-B, H8571-C, H8575-D, H8575-E.
The second picture shows the H8571-J.
H8575-A etc.
H8571-J
Since 1985, the Electrical Industries Association (EIA), decided to replace
the 'RS-' identifier with EIA', therefore RS-232-C has been replaced by
EIA-232-D. These two standards are compatible with each other. The
EIA-232-D/CCITT V.24/V.28 standard was originally designed to specify the
connection between a local interface and a modem. It was not intended to be used
for connecting to terminals over long distances. The maximum specified length is
50 feet (15m), and shielded cable must be used in order to meet the requirements
of FCC and VDE Radio Frequency Interference (RFI) regulations.
Although cable lengths of greater than 50 feet can be used with reasonable
success, cable capacitance, noise, and ground potential difference restrict the
line speed as the distances increase.
As a consequence of this, the performance of long distance communications to
a terminal using EIA-232 does not meet today's requirements for terminal wiring.
DEC423 is a superset of the RS-423-A/CCITT V.10 standard. RS-423-A has a
different grounding and signal return path arrangement from EIA-232-D, as well
as using different line driver and receiver chips. DEC423 uses line driver and
receiver chips which have better filtering and tighter level tolerances than
those specified by RS-232-A. In addition, DEC423 devices include transient
suppressors for electrical overstress (EOS) and electro-static discharge (ESD)
protection. DEC423 devices may also be connected with unshielded cable. The
features provided by DEC423 devices provide reliable data communication over
increased distances, typically 1000 feet (300m).
Table of Distances Between Devices DEC423 uses the RJ45 Modular Jack, or the Modified Modular Jack (MMJ)
connector instead of the much larger D-type connector defined in RS-449. DEC423
is signal compatible with the EIA-232-D standard when used for data-leads-only
interconnection, ie, interconnection between devices using the different
standards is possible but the speed and distance restrictions of EIA-232-D will
still apply. DEC423 should always be used be used in preference to EIA-232-D for
direct terminal connection over extended distances.
EIA-232-D terminals can be connected to DEC423 devices using either an
H8571-x passive adapter, or a H3105-B active adapter. The H3105-B active
terminal adapter is necessary when using an EIA-232-D terminal with a DEC423
interface if the longer cable lengths obtainable with DEC423 are required.
There are two types of DEC423 cable available: the H8245/6 "Building" cable
which is of twisted pair construction, and the H8240 "Office" or flat 6-core
ribbon cable. BC16E cables are pre-terminated lengths of H8240 cable. The
maximum length for DEC423 cabling has been given, for example, 1000 feet at
19,200 Baud, and within this, 50 feet is the usually recommended maximum length
of "office" cabling, however 100 feet would probably give satisfactory results.
DEC422 also incorporates EOS/ESD protection and RS-422 compatible drivers and
receivers, thus DEC422 is ideal for use in high noise environments. DEC422,
which uses differential line drivers supports cable lengths of up to 4000 feet
(1200m) at all supported speeds.
where
DTE = Data Terminal Equipment (terminal or computer system), and
DCE = Data Communications Equipment (typically a modem).
Signal Levels used with EIA-232.
(EIA-232 is an unbalanced system with a common return).
For Data :
An EIA-232 transmitter generates a voltage of between -5 and -25 volts for a
MARK (logic 1), and between +5 and +25 volts for a SPACE (logic 0).
An EIA-232 receiver recognizes voltages of above +3 volts as spaces, and
voltages more negative than -3 volts as marks.
For Control :
Between -3 and -25 volts for a NEGATION, and between +3 and +25 volts for an
ASSERTION.
EIA-423 :
EIA-423 is also an unbalanced system, but unlike EIA-232, separate return
wires are used for both transmit and receive data. With a EIA-423 transmitter
the voltage must be at least +4 volts for a space, and -4 volts for a mark.
EIA-422 :
EIA-422 uses two separate wires for each signal, and is a balanced system.
A mark is differentiated from a space by the polarity of one wire with
respect to the other rather than with respect to ground.
H8584-AC
MMJ adapter. A small adapter which plugs directly in to the 8-way MJ port of
a DECserver and converts it to a 6-way MMJ. A BC16E (crossed) cable could then
be used for a terminal or printer connection. The wiring for this adapter is
straight.
H8584-AB Passive Adapter for Apple Mcintosh.
This passive adapter is contained in a small moulded plastic housing and has
the following connectors:
(a) 6-way MMJ (Modified Modular Jack), female.
b) 8-pin DIN, male.
This adapter may be attached to an Apple Macintosh LOCAL (DIN) socket, and so
"convert" it to a 6-way MMJ connector suitable for connection to a Digital
terminal server via a BC16E cable.
Wiring - straight through. H8585-AA
PC Adapter. Has a 9-way female D-type connector which plugs into a PCs serial
BC16E Cablen 8-way MJ. A BN25G (straight through) cable would then be used to
connect the 9-way communications port of the PC to a DECserver. The wiring for
the adaptor is crossed.
H8585-AB
Low speed (below 9,600 baud) Modem Adapter. Has a 25-way male D-type
connector which plugs into a modem, and an 8-way MJ. A BN25G (straight through)
cable would be used to connect the modem plus adapter to a DECserver. The wiring
for this adapter is straight through.
H8585-AC
Modem Adapter (for 9,600 baud or higher). Has a 25-way male D-type connector
which plugs into a modem, and an 8-way MJ.
A BN25G cable would then be used to connect the modem plus adapter to a
DECserver. Wiring is straight through.
DECserver Cable and Adapter Reference Guide.
Here is a picture of, clockwise from center top, the H8585-AA, H8585-AC,
H8584-AA, and the H8585-AB:
H8585-AA etc
1. 10BaseT Configuration
2. DEC423 Configuration.
Digital use a multi-standard 50-pin, male, D-type connector for synchronous
communication
connections. This connector is attached to the following devices:- Note. The DEC WANrouter 90EW, the DECbrouter 90, and the RouteAbout family
have a different type of 50-way connector (micro-Champ), and require different
adaptor cables. (see entriy BC12x-xx).
Contained within the 50-way connector are the necessary signals for
connection to the following communications standards:
EIA-422 EIA-423
X.21 V.35
V.24 (EIA-232-D) BTs KILOSTREAM
To extract the necessary signals for each of 18 232 Signal/Pin Designations
the other to an " extender" cable, which in turn is connected to the
communications connection
Summary of adapter and extender cables for use with the standard Synchronous
Interface: * Incompatible with BT's Kilostream network.
** For use with BT's Kilostream network, and Mercury Communications
equivalent.
*** The BS23V-02 Adaptor Cable Kit is very similar to the BS19D-02, and
either of these may generally
be used for EIA-232 connections.
Multi-Standard Interface Pin Configuration Where (A) and (B) are wires A(+ve), and B(-ve), of a twisted pair.
1. Thickwire Ethernet Cable
Ready to use pre-assembled Thickwire cables are available with part number
BNE2A-xx, and BNE2B-xx, where -xx specifies a particular length. Pre-assembled
lengths of BNE2x-xx cable may be joined together using a Barrel Connector part
number 12-19817-01. A ThickWire segment must be properly terminated with 50-Ohm
impedance terminators. Thickwire Terminator is part number 12-19816-01.
Thickwire Ethernet cable may also be custom made using the following components:
Cable
EO-BNE2B-ME 500
metre length of low loss, NI, coaxial cable with PVC jacket, and fitted with
male N-type ends.
Or
E0-BNE2A-ME 500
metre length of low loss, NI, coaxial cable with TEFLON jacket, and fitted with
male N-type ends.
TEFLON jacketed cable is plenum-rated (UL-listed CMP), and PVC jacketed cable
(Tape drive for use in use in non-environmental airspaces.
End Connectors
12-19118-00
One N type RG8.8A Plug
Testing
It is recommended that a custom made length of Thickwire cable should be
tested prior to use using a TDM (Time Domain Reflectometer), this is
particularly important for segments which are to be heavily loaded.
2. ThinWire Ethernet Cable
Ready to use ThinWire cables with PVC jackets are available with part number
BC16M-xx . ThinWire
cables may be joined together using a Barrel Connector part number E0-H8224. A
ThinWire segment must be properly terminated with 50 Ohm impedanance
terminators. ThinWire Terminator part number is E0-H8225. To attach a station to
ThinWire Ethernet a "T" Connector ThinWire part number E0-H8223 must be fixed
directly to that station, and the lengths of cable, or length of cable plus
terminator will be attached to the "T" connector.
ThinWire Ethernet cable may be custom made using the following components:
Cable
H8243-A 1000 feet spool of ThinWire coaxial cable with PVC jacket.
Or
Cable H8244-A 1000 feet spool of ThinWire coaxial cable with TEFLON jacket.
End connectors
E0-H8222 one male pin BNC connector.
Tools
The H8242 Tool Kit contains the necessary strippers and crimp tool to attach
the end connectors to the raw cable.
The fibre optic cables supplied by Digital such as the BN24B, BN24D, or BN24E
are for internal use ONLY because they do not have a weather proofed or amoured
jacket. 90% of fibre cable applications require that the cable be run externally
either in a duct or even directly buried in the ground. It is a specialist job
to define the cable required, the possible maximum lengths and the termination
for a particular site and a particular application, so an in depth site survey
will be required. Customers who do not have access to the necessary skills
should be directed to their local Digital office or their account manager to IBS
(Intelligent Building Services) who can provide a total installed and tested
solution.
In general, the Digital recommendation for a new fibre optic installation is
for 62.5/125 micron, dual window, graded-index profile, multimode glass-on-glass
construction (EIA Class 1A). Digital is optimising its multimode fibre products
for 62.5/125 fibre.
Connectors
Types of fibre-optic connectors in current use:-
ST - Bayonet
This type of connector has a "push-twist" fastening action. It virtually
replaced the older SMA-type which has a screw-on fastening. The ST provides a
higher reliability and a better connection than the SMA.
ST - Push-pull
The push-pull construction provides easy insertion and high repeatability.
SC
This connector is physically smaller than the ST-type, has rectangular
cross-section, and has a push-pull fixing action. There is both a simplex and a
duplex version.
Digital is using SC connectors in certain products because of the smaller
physical size and also industry demand. The SC connector is specified in TIA/EIA
568-A. The duplex SC socket is considerably smaller than the widely used MIC
socket.
MIC
The FDDI MIC (Media Interface Connector) is a duplex connector. The MIC is
keyed, and is field programmable for the appropriate type of FDDI connection.
FC/PC
Digital chose the FC/PC connector for SM (Single Mode) fibre applications.
One of the key selection factors was that FC-PC is physically different to the
ST and thus customers could not inadvertently plug SM into MM (Multi Mode)
sockets. However the newest physical media dependant o 18 232 Signal/Pin
Designations the other to an " extender" cable, which in ptions (PMDs), for example the
DEFXS-BA, use ST connectors for SMF.
Additional Note For FDDI
FDDI modules which utilise Multimode Fibre (MMF) use both pairs of ST or SC
connectors and also Media Interface Connectors (MIC). Modules utilizing Single
Mode Fibre (SMF) use FC-PC connectors.
Conductors
MMF modules use 62.5/125 micron fibre. SMF modules use 8-10/125 micron fibre.
The maximum possible cable length between nodes for MMF is 2 km. The maximum
possible cable length between nodes for SMF is 40 km.
FDDI Device Connector Types
The following is list of FDDI device connector types was contributed by Mike
Collins of the Networks Business Unit @REO. DECconcentrator 900 There are two types of DSSI connectors :
BA400 series enclosures, including the R400X and B400X expansion enclosures.
BA200 series enclosures, including the R215F expansion pedestal for housing
up to 3 Integrated Storage Elements or ISEs.
R23RF (BA23 type enclosure for housing up to two Removable Storage Elements
or RSEs).
BA23 and BA123 enclosures fitted with KFQSA adapters.
VAX 6000, 7000, 9000, 10000 bulkheads, DSSI Storage Array Cabinets, Tabletop
TF85.
There are three types of inter-cabinet cables :
There are two types of inter-cabinet Cable Kits :
Cable Kit Part Numbers Inter Cabinet Cable Part Numbers
BC21M-03, -09, -16, -25 (feet).
BC21Q-3F (3.5 feet), -06, -09, -16, -25, -50 (feet).
BC22Q-09, -16, -25 (feet).
BC29R-06, -09, -16, -45 (feet)
BC29S-06, -09, -16, -30, -45, -60 (feet)
BC29T-03, -06 (feet)
BC29U-02 (feet)
BC29V-01, -06, -16 (feet) List of DSSI Device Connector Types
the other to an " extender" cable, which in ptions (PMDs), for example the DEFXS-BA, use
ST connectors for SMF.
Additional Note For FDDI
FDDI modules which utilise Multimode Fibre (MMF) use both pairs
of ST or SC connectors and also Media Interface Connectors (MIC).
Modules utilizing Single Mode Fibre (SMF) use FC-PC connectors.
Conductors
MMF modules use 62.5/125 micron fibre. SMF modules use 8-10/125
micron fibre.
The maximum possible cable length between nodes for MMF is 2 km.
The maximum possible cable length between nodes for SMF is 40
km.
FDDI Device Connector Types
The followin MR
KFMSA-BA XMI/DSSI Adapter MR
KFMSB-AA XMI/DSSI Adapter MR
KFPSA-AA PCI/DSSI Adapter MR
KFQSA-xx Q-bus/DSSI Adapter PS
HSD30-xx DSSI/SCSI Controller MR
HSD05-xx DSSI/SCSI Adapter MR
(The information in this appendix has been supplied by Alan Braseby of the
Systems Business Unit @REO
There are four types of SCSI connector in current use
List of connector types used with system/expansion boxes List of connector types used with Options
the other to an " extender" cable, which in ptions (PMDs), for example the DEFXS-BA, use
ST connectors for SMF.
Additional Note For FDDI
FDDI modules which utilise Multimode FibreHD 50 F)
PC4XR-CC Low-density (LD)
PCTAZ-AB 50-pin high-density female (HD 50 F)
PCTAZ-AD Low-density (LD)
PCTAZ-CD Low-density (LD)
PMAZ/PMAZB 50-pin high-density female (HD 50 F)
PMAZC 50-pin high-density female (HD 50 F)
SCSI Cable Summary.
LD = Low Density, or Centronics type connector. HD= High
Density, or Honda connector. VHD = Very High Density (0.8 mm pitch)
Notes.
In general, all SCSI cables with a "BC" designation are not wired to Fast
SCSI specifications, whereas virtually all cables made with a "BN" designation
are wired to Fast SCSI specifications, i.e.they have the correct impedance and
internal wiring which is suitable for use with the demanding Fast SCSI.
SCSI Terminators
H8574-A Single-ended, 8-bit SCSI bus Terminator with 50-pin, male,
low-density connector.
Example usage: attached to a BN21V-02 adapter cable to terminate a
single-ended SCSI bus at an end position controller, this would facilitate the
removal of that controller without interrupting the bus.
12-29635-01 Single-ended, 8-bit SCSI bus Terminator with 68-pin,
female, high-density connector.
Example usage: supplied with early workstations and InfoServer 150 for bus
termination.
H879 -AA FWD (Fast Wide Differential) SCSI bus Terminator with 68-pin,
high-density, male connector.
Example usage: attached to an H885 -AA Tri-link Connector Block to terminate
a FWD SCSI at an end position controller, this would facilitate removal of that
controller without interrupting the bus.
12-37004-04
50-pin, active single-ended terminator.
SCSI Connector Block
H885 -AA FWD SCSI Tri-link Connector Block with three 68-pin,
high-density connectors, one one side one male, on the other side two female. A
typical configuration would be: DSSI Terminator
12-31281-01 DSSI bus Terminator with 50-pin, female MR type connector.
Typical usage: with a 12-39921-02 DSSI Tri-link Adapter attached to a DSSI
controller/adapter to facilitate the removal of that adapter without
interrupting the DSSI bus.
DSSI Connector Block
12-39921-02 DSSI Tri-link Connector Block which is supplied attached
to the DSSI port of DSSI controllers/adapters such as the HSD05, HSD10, HSD30,
HS1CP. The adapter presents two 50-pin, male, MR connectors, to which would be
attached a DSSI cable and a 12-31281-01 DSSI terminator, or two DSSI cables.
USER COMMENTS PLEASE
Your comments and suggestions will help us to improve the quality, and
usefulness of this guide. We would very much appreciate it if you would take the
time to provide us with feed-back : BN21N SCSI Cable
BN21P-0B SCSI "Y" Cable
BN21P-02 SCSI Adapter Cable
BN21R Fast SCSI Cable
BN21V SCSI "Y" Adapter Cable
BN21W SCSI "Y" Adapter Cable
BN21X SCSI Adapter Cable
BN21Y SCSI "Y" Adapter
BN22E-2E Power Cable
BN23G Fast SCSI Cable
BN24A ThinWire Daisy Chain Cable
BN24B FDDI To FDDI Cable Assembly
BN24D FDDI To ST Cable Assembly
BN24E Dual ST Cable Assembly
BN24F 10BaseT Office Cable
Pin Pin
1 3
2 6
3 1
6 2
BN24H DEC423 Office Cable
Signal 6-Way MMP 8-Way MP Signal
DTR 1 8 DSR
Tx Data 2 2 Rx Data
Tx Ground 3 1 Rx Ground
Rx Ground 4 3 Tx Ground
Rx Data 5 6 Tx Data
DSR 6 7 DTR
BN24J DEC423 Equipment Cable
Signal 6-Way MMP 8-Way MP Signal
DTR 1 7 DTR
Tx Data 2 6 Tx Data
Tx Ground 3 3 Tx Ground
Rx Ground 4 1 Rx Ground
Rx Data 5 2 Rx Data
DSR 6 8 DSR
BN24K DEC423 Equipment Cable
BN24L DEC423 Equipment Cable
BN24N DEC423 Equipment Cable
BN24Q 100BaseT or 10BaseT Cable
Connector 1 Connector 2
pin pin
1 3
2 6
3 1
4 7
5 8
6 2
7 4
8 5
BN25G Data Grade Equipment Cable
Pin 10BaseT Signal
1 Tx+
2 Tx-
3 Rx+
4 N/C
5 N/C
6 Rx-
7 N/C
8 N/C
BN25H Unshielded Office Cable for TP FDDI.
Plug A Plug B
1 7
2 8
3 3
4 4
5 5
6 6
7 1
8 2
BN26M High Performance Office Cable
8-Way MP 8-Way MP
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
BN26N 10BaseT Office Cable
8-Way MP 8-Way MP
1 3
2 6
3 1
6 2
BN26R Octopus Cable
BN26S Shielded Office Cable for TP FDDI.
Plug A Plug B
1 7
2 8
3 3
4 4
5 5
6 6
7 1
8 2
Shield Shield
BN26U 10BaseT "Octopus" Adapter Cable.
Pin Signal
1 Rx+
2 Rx-
3 Tx+
6 Tx -
BN31G SCSI Cable
BN31K KZPSC Cable/Bulkhead Assembly
BN31L Single-ended SCSI Cable
BN31M Single-ended SCSI Cable
BN31S Single-ended SCSI Cable
BN31V SCSI Cable
BN31W SCSI Cable
BN34A Dual ST-SC Fibre-Optic Cable
BN34B Dual SC-SC Fibre-Optic Cable
BN34C Dual ST-ST Fibre-Optic Cable
BN34D IC-SC Fibre-Optic Cable
BN36A SCSI Adapter Cable
BN41A DECserver900GM Octopus Cable.
Pin Signal
2 Tx Data
3 Rx Data
4 RTS
5 CTS
6 DSR
7 GND
8 DCD
12 SMI
20 DTR
22 RI
23 DSRS
BN41B DECserver900GM Octopus Cable.
1 Rx Data Common
2 Rx Data
3 Tx Data Common
4 CTS
5 RTS
6 Tx Data
7 DTR
8 DSR
BN41C DECserver900GM Adapter Cable
Connector 1 Connector 2 Signal Name
1 1 Tx Data 1
5 26 Tx Data COM 1
2 2 Rx Data 1
36 27 Rx Data COM 1
3 3 DSR 1
37 28 DTR 1
5 4 Tx Data 2
39 29 Tx Data COM 2
6 5 Rx Data 2
40 30 Rx Data COM 2
7 6 DSR 2
41 31 DTR 2
9 7 Tx Data 3
43 32 Tx Data COM 3
10 8 Rx Data 3
44 33 Rx Data COM 3
11 9 DSR 3
45 34 DTR 3
13 10 Tx Data 4
47 35 Tx Data COM 4
14 11 Rx Data 4
48 36 Rx Data COM 4
15 12 DSR 4
49 37 DTR 4
17 13 Tx Data 5
51 38 Tx Data COM 5
18 14 Rx Data 5
52 39 Rx Data COM 5
19 15 DSR 5
53 40 DTR 5
21 16 Tx Data 6
55 41 Tx Data COM 6
22 17 Rx Data 6
56 42 Rx Data COM 6
23 18 DSR 6
57 43 DTR 6
25 19 Tx Data 7
59 44 Tx Data COM 7
26 20 Rx Data 7
60 45 Rx Data COM 7
27 21 DSR 7
61 46 DTR 7
29 22 Tx Data 8
63 47 Tx Data COM 8
30 23 Rx Data 8
64 48 Rx Data COM 8
31 24 DSR 8
65 49 DTR 8
34 > 68 CABLE ID
BN41D DECserver900GM Adapter Cable
Pin Signal
2 Tx Data
7 Tx Data COM
3 Rx Data
7 Rx Data COM
6 DSR
20 DTR
5 CTS
4 RTS
BNCIA CI Cable Set
BNE2A / BNE2B Ethernet Cable
BNE3H / K / L / M and BNE4C / D and BNE4G - Transceiver Cables
Pin Signal Pin Signal
1 Shield 9 Collision Presence -
2 Collision Presence + 10 Transmit -
3 Transmit + 11 Reserved
4 Reserved 12 Receive -
5 Receive + 13 Power
6 Power Return 14 Reserved
7 Reserved 15 Reserved
8 Reserved
E0-BNE4C-02 2m PVC Office Cable
E0-BNE4C-05 5m PVC Office Cable
E0-BNE3H-05 5m PVC Cable
E0-BNE3L-05 5m Teflon Cable
E0-BNE3H-10 10m PVC Cable
E0-BNE3L-10 10m Teflon Cable
E0-BNE3H-20 20m PVC Cable
E0-BNE3L-20 20m Teflon Cable
E0-BNE3H-40 40m PVC Cable
E0-BNE3L-40 40m Teflon Cable
E0-BNE4D-02 2m PVC Office Cable
E0-BNE4D-05 5m PVC Office Cable
E0-BNE3K-05 5m PVC Cable
E0-BNE3M-05 5m Teflon Cable
E0-BNE3K-10 10m PVC Cable
E0-BNE3M-10 10m Teflon Cable
E0-BNE3K-20 20m PVC Cable
E0-BNE3M-20 20m Teflon Cable
E0-BNE3K-40 40m PVC Cable
18 DSR 6
57 43 DTR 6
25 19 Tx Data 7
59 44 Tx Data COM 7
26 20 Rx Data 7
60 45 Rx Data COM 7
27 21 DSR 7
61 46 DTR 7
29 22 Tx Data 8
63 47 Tx Data COM 8
30 23 Rx Data 8
64 48 Rx E0-BNE3M-40 40m Teflon Cable
BS19D EIA-232 Adapter Cable Kit
BS23V V.24 / V.28 Adapter Cable Kit
50-Way Signal Name 25-Way 50-Way Signal Name 25-Way
Pin Pin Pin Pin
1 CODE GROUND * 22 CLOCK 24
3 CODE 1 * 33 DTR 20
8 Tx DATA 2 34 DSR (A) 6
11 Rx DATA (A) 3 35 DSR (B) #
12 Rx DATA (B) # 36 RTS 4
13 LOCAL LOOP 18 37 DCD/I (A) 8
14 SMI 12 38 DCD/I (B) #
15 TEST 1 25 39 CTS (A) 5
17 RI 22 40 CTS (B) #
16 REM. LOOP 21 41 DCE GROUND #
18 Rx CLOCK (A) 17 44 DTE GROUND 7,#
19 Rx CLOCK (B) # 50 SPEED 23
20 Tx CLOCK (A) 15
21 Tx CLOCK (B) #
H8240 Flat 6-Conductor Cable
H8240-A UTP High Performance Data Grade Cable
H8240-B STP High Performance Data Grade Cable
H8245-A and H8246-A UTP Standard Data Grade Cable
H8245-C and H8246-C UTP High-Performance Data Grade Cable
H8245-D and H8246-D STP High-Performance Data Grade Cable
H0401 Crossover Switch
H8571/H8575 DEC423 Passive Adapters
H8575-A Schematic
H8575-B Schematic
H8571-C Schematic
H8575-D Schematic
H8575-E Schematic
H8571-J Schematic
Appendix A EIA Standards, Speed and Distance
Device Type Speed: 4.8 Kbaud 9.6 Kbaud 19.2 Kbaud 38.4 Kbaud
DEC423 device to:
DEC423 device 3000 ft 3000 ft 1000 ft 280ft
DEC423 to EIA-232-D 200 ft 200 ft 50 ft 50 ft
DEC422 to DEC422 4000 ft 4000 ft 4000 ft 4000 ft
Appendix B - EIA- 18 232 Signal/Pin Designations
Pin Signal Description Signal Direction Common Abbreviation
1 Protective Ground to DCE & DTE GND
2 Transmitted Data to DCE TD, Tx
3 Received Data to DTE RD, Rx
4 Request To Send to DCE RTS
5 Clear To Send to DTE CTS
6 Data Set Ready to DTE DSR
7 Signal Ground/Common Return to DCE & DTE SG
8 Received Line Signal or
Data Carrier Detector to DTE DCD or CD
9 Reserved for +ve test voltage to DTE
10 Reserved for -ve test voltage to DTE
11 Unassigned
12 Secondary Received Line Signal to DTE SMI (Data Carrier) Detector
13 Secondary Clear To Send to DTE
14 Secondary Transmitted Data to DCE
15 Transmit Clock to DTE TC
16 Secondary Received Data to DTE
17 Receive Clock to DTE RC
18 Reserved
19 Secondary Request To Send to DCE
20 Data Terminal Ready to DCE DTR or TR
21 Signal Quality Detector to DTE SQ
22 Ring Indicator to DTE RI
23 Data Signal Rate Selector to DCE DSRS
24 External Transmit Clock to DCE XTC
25 Reserved. Typically used by to DCE OOS (Out Of Service).
modem manufacturers as Terminal Busy
Appendix C - Terminal Server Adapters
H8584-AA Schematic
MMJ Pin Signal DIN Pin Signal
1 DTR 1 Handshake Output
2 TD+ 3 Transmit Data
3 TD- 4 Frame Ground
4 RD- 8 Receive Data +
5 RD+ 5 Receive Data
6 DSR 2 Handshake Input
6 Not Connected
7 Not Connected
H8585-AA Schematic
H8585-AB Schematic
H8585-AC Schematic
DECserver Reference Guide
Appendix D - OPEN DECconnect Sample Configurations
Sample Configuration
Sample Configuration
Appendix E Digital's Multi-Standard 50-pin Synchronous
Interface for WAN
(Wide Area Network) Devices.
DECNIS (Some Modules) MUXserver 90
DEMSA MicroServers MUXserver 300 series
DEMSB MicroServers DECmux 300 series
DSV11 Controller DEC WANrouter 90
DEC WANrouter 150/250 Leafbridge
Communications Standard Adapter Cable Extender Cable
EIA-422 BC19B-02 BC55D-xx
X.21 BC19C-02* BC22Z-xx
EIA-232-D BS19D-02*** BC22F-xx
EIA-423 BC19E-02 BC55D-xx
V.35 BC19F-02 BC19L-xx
BT Kilostream BC22X-02** BC22Z-xx
50-Way Signal Name 50-Way Signal Name
Pin Pin
1 CODE GROUND 26 V.35 CLOCK (B)
2 CODE 0 27 V.35 Rx DATA (A)
3 CODE 1 28 V.35 Rx DATA (B)
4 CODE 2 29 V.35 Tx DATA (A)
5 CODE 3 30 V.35 Tx DATA (B)
6 Tx DATA (A) 31 V.35 Rx CLOCK (A)
7 Tx DATA (B) 32 V.35 Rx CLOCK (B)
8 Tx DATA 33 DTR
9 RTS/C (A) 34 DSR (A)
10 RTS/C (B) 35 DSR (B)
11 Rx DATA (A) 36 RTS
12 Rx DATA (B) 37 DCD/I (A)
13 LOCAL LOOP 38 DCD/I (B)
14 SPEED INDICATE 39 CTS (A)
15 TEST I 40 CTS (B)
16 REM. LOOP 41 DCE GROUND
17 RI 42 TEST 1
18 Rx CLOCK (A) 43 TEST 2
19 Rx CLOCK (B) 44 DTE GROUND
20 Tx CLOCK (A) 45 DTR (A)
21 Tx CLOCK (B) 46 DTR (B)
22 CLOCK 47 CLOCK (A)
23 V.35 Tx CLOCK (A) 48 CLOCK (B)
24 V.35 TX CLOCK (B) 49 TEST 3
25 V.35 CLOCK (A) 50 SPEED
Synchronous Cables Summary
Cable Summary
Appendix F Ethernet Cable Parts
Appendix G - "Confusable" Cable Summary
Summary Part 1
Summary Part 2
Appendix H - Fibre Optics Notes
FDDI Devices for EISA
DEFEA-AA, MMF; SAS MIC
DEFEA-DA, MMF, MMF; DAS MIC, MIC
DEFEA-UA, UTP; SAS RJ45
FDDI Devices for PCI
DEFPA-UA, UTP; SAS RJ45
DEFPA-MA, UTP; DAS Pair of RJ45
DEFPA-AA, MMF; SAS Dual SC
DEFPA-DA, MMF, MMF; DAS Pair of Dual SC
FDDI Devices for TurboChannel
DEFTA-FA, MMF; SAS ST (pair of)
DEFTA-AA, MMF; SAS ST (pair of)
DEFTA-DA, MMF, MMF; DAS ST (pair of)
DEFTA-UA, UTP; SAS RJ45
DEFZA-AA, MMF; SAS ST (pair of)
DEFZA-CA, Co-ax or STP; SAS BNC, or, 9-way D-type (switchable)
FDDI Modules for Futurebus+
DEFAA-AA, MMF; SAS MIC
EFAA-DA, MMF, MMF; DAS MIC, MIC
FDDI Devices for Q-bus
EFQA-SF/SA, 2xMMF; SAS MIC
EFQA-DF/DA, MMF; DAS MIC
FDDI Devices for XMI
EMFA-AA, MMF; SAS MIC
EMFA-AB, MMF; SAS MIC
DECconcentrator 500 Modules
EFCN-MB/MH, MMF, MMF MIC + MIC
EFCN-CA/CF, SMF, MMF FC-PC + MIC
EFCN-DA/DF, MMF, SMF MIC + FC-PC
EFCN-EA/EF, SMF, SMF FC-PC + FC-PC
EFCN-LA/LF, 4 x MMF 4 x ST pairs
EFCN-NA/NF, 4 x MMF 4 x MIC
EFCN-HA/HF, 6 x MMF 6 x MIC
EFCN-FA/FF, (2 x MMF) + (2 x SMF)(2 x MIC) + (2 x FC-PC)
EFCN-TA/TF, 6 x Copper Co-ax 6 x BNC
EFCN-SA/SF, 6 X Copper STP, 6 x 9-way D-type
DEF6M-MA MMF 6 x MIC
DEF6U-MA UTP 6 x RJ45
DEFHM-MX MMF 12 x SC pairs
DEFHM-MM MMF 12 x SC pairs + 2 x MIC
DEFHU-MX UTP 12 x RJ45
DEFHU-MU UTP 14 x RJ45
DEFHU-MM UTP + MMF 12 x RJ45 + 2 x MIC
DEFHU-MS UTP + SMF 12 x RJ45 + 2 x SC
DECbridge 500 series
EFEB-AD MMF; SAS MIC
EFEB-AT SMF; SAS FC-PC
EFEB-DB MMF, MMF; DAS MIC, MIC
EFEB-DN SMF, MMF; DAS FC-PC, MIC
EFEB-DQ MMF, SMF; DAS MIC, FC-PC
EFEB-DT SMF, SMF; DAS FC-PC, FC-PC
DECbridge 600 series
EFEB-TB MMF; SAS MIC
EFEB-TT SMF; SAS FC-PC
EFEB-LB MMF, MMF; DAS MIC, MIC
EFEB-LN SMF, MMF; DAS FC-PC, MIC
EFEB-LQ MMF, SMF; DAS MIC, FC-PC
EFEB-LT SMF, SMF; DAS FC-PC, FC-PC
MOD PMD (Physical Media Dependent) FDDI Modules for use in DECconncentrator 900, DEChubONE MX,
and GIGAswitch/FDDI
DEFXM-AA MMF MIC
DEFXS-AA SMF FC-PC
DEFXS-BA SMF ST
DEFXU-AA/BA UTP RJ45
DEFXM-SC MMF Dual SC
DECswitch 900EF
DEFBA-MA MMF; DAS MIC, MIC
Appendix I - DSSI Connections
CK-SF100-LP contains BC22Q-09 MR/PS cable, plus DSSI terminator.
CK-SF100-LM contains BC21Q-09 MR/MR cable, plus DSSI terminator.
CK-SF100-L3 contains BC21Q-25 MR/MR cable, plus DSSI terminator.
CK-SF100-L4 contains BC22Q-25 MR/PS cable, plus DSSI terminator.
CK-SF100-L5 contains BC21Q-16 MR/MR cable, plus DSSI terminator.
CK-SF100-L6 contains BC22Q-16 MR/PS cable, plus DSSI terminator.
CK-SF200-LP contains BC22Q-09 MR/PS cable, plus internal BC21R-5L cable.
CK-SF200-LM contains BC21Q-09 MR/MR cable, plus internal BC21R-5L cable.
CK-SF200-L3 contains BC21Q-25 MR/MR cable, plus internal BC21R-5L cable.
CK-SF200-L4 contains BC22Q-25 MR/PS cable, plus internal BC21R-5L cable.
CK-SF200-L5 contains BC21Q-16 MR/MR cable, plus internal BC21R-5L cable.
CK-SF200-L6 contains BC22Q-16 MR/PS cable, plus internal BC21R-5L cable.
CK-SF200-L7 contains BC21Q-50 MR/MR cable, plus internal BC21R-5L cable.
CK-SF200-L8 contains BC22Q-50 MR/PS cable, plus internal BC21R-5L cable.
DSSI Device Connector Type
SF1xx Pedestals MR
SF2xx Cabinets MR
DECarray 300 Cabinets MR
SF400 Cabinets MR
TF8x -TA Tabletop enclosures MR
R400X Expansion Enlosure PS
SF12 Expansion Enclosure PS
VAX/DEC 6000/7000 MR
VAX/DEC 4000 PS
KFDDA-AA VAX 4000-100A/DSSI Adapter PS
KFDDA-AF VAX 4000-100A/DSSI Adapter PS
KFDDA-BA VAX 4000-100A/DSSI Adapter PS
KFDDB-Ax VAX 4000-500A,600A,700A/DSSI Adapter PS
KFESA-AA EISA/DSSI Adapter 18 232 Signal/Pin Designations
Appendix J SCSI Device Connector Types
ApplicationDEC433W 50-way high-density female (HD 50 F)
BA346 50 pin high density female (HD50 (F)
BA350 50-way high-density female (HD 50 F)
BA353 50-way high-density female (HD 50 F)
BA356 68-way high-density female (HD 68F)
BA356, 8 bit I/O module 50 pin high-density female (HD50F)
BA362/364 * 68 pin high density female (HD68F)
AlphaSatation 200/250/255/400 50-way high-density female (HD 50F)
AlphaStation 500/600 68 pin high density female (HD 68F)
AlphaServer 400/1000/2000/2100 50-way high density female (HD 50F)
DEC 2000-300/500 50-way high-density female (HD 50 F)
(Adaptec 1740 EISA
controller, PB2HA-SA).
DEC 3000-300 50-way high-density female (HD 50 F)
DEC 3000-400/500/600/ Low-density (LD)
700/800/900 (for on-board
SCSI controller).
DEC 4000-6x0/7x0 Low-density (LD)
(Preferred SCSI cable: BN21R).
DECstation 3100 68-way high-density male (HD 68 M)
DECstation/system 50-way high-density female (HD 50 F)
5000 model 20,25,33,
50,125,133,240,260
DECsystem 5100 Low-density (LD)
Digital 2100 Server 50-way high-density female (HD 50 F)
A500 MP systems.
Infoserver 100/150 68-way high-density male (HD 68 M)
Infoserver 1000 50-way high-density female (HD 50 F)
Infotower 1000 Low-density (LD)
MicroVAX 3100 Low-density (LD)
model 10,20,10e,20e
model 30,40,80,90
MD30C scanner Low-density (LD)
RRD45 Tabletop Low-density (LD)
RWZ21 Low-density (LD)
SZ03 Low-density (LD)
SZ12 Low-density (LD)
SZ16 Low-density (LD)
SZ18 Low-density (LD)
SZ100/SZ106/SZ107 Low-density (LD)
TL810 High-density (HD68 F)
TL820 Low-density (LD)
TKZ08/TKZ09 Low-density (LD)
TZK10/TZK11 Low-density (LD)
TZK60 Low-density (LD)
TLZ04/TLZ06 Low-density (for tabletop drive) (LD)
TLZ07/TLZ09 Low-density (for tabletop drive) (LD)
TLZ6L/TLZ7L Low-density (LD)
TSZ05/TSZ07 Low-density (LD)
TZ87/88N-TA Low-density (LD)
Tabletop drive.
TZ877/TZ887-A* Low-density (LD)
Tape drive for use in SW500/
800 cabinet.
With this option, a converter
cable is supplied to make it
HD50 compatible. Use of the
BN21H is recommended in SW500/800
for the first drive, and a BC19J-03
for connecting the second tape drive
to the first drive.
VAX 4000-100 series Low-density (LD)
VAXstation 3100 68-way high-density male (HD 68 M)
model 30,40,38,48,76
VAXstation 4000 Low-density (LD)
model VLC/60/90
*Note. A straight entry cable must be used to connect into the BA362/364.
DWZZA-AA Low-density, and also (S/E port: LD)
68-way high-density (Differential port: HD 68)
DWZZB-AA High density (S/E port: HD 68
(Differential port: HD68)
FR-PCTAR-AA No external connector.
1 channel SCSI raid controller
(MyleX) (EISA bus).
FR-PCTAR-AB 50-pin high-density female (HD 50 F)
1 channel SCSI raid controller
(Mylex) (EISA bus).
FR-PCTAZ-AE 50-pin high-density female (HD 50 F)
FR-PCTAZ-CB 50-pin high-density female (HD 50 F)
FR-PCTAZ-DA 50-pin high-density female (HD 50 F)
HSZ10-AX 68-pin high-density female (HD 68 F)
HSZ40 68-pin for host port. (HD68 F)
KZDDA-AA Low-density (LD)
KZESC-xx 50-pin high density (HD50 F)
KZMSA 50-pin high-density female (HD 50 F)
KZPAA 50-pin high density (HD50 F)
KZPDA 68-pin high density female (HD68F)
KZPSA-BB 68-pin high-density female (HD 68 F)
KZPSC-xx 68-pin very-high-density female (VHD 68 F)
KZTSA-AA 68-pin high-density female (HD 68 F)
KZQSA-xx Low-density (LD)
PB2HA-SA 50-pin high-density female ( 18 232 Signal/Pin Designations
Appendix K Summary of SCSI Cables
Appendix L SCSI and DSSI Terminators and Tri-Link Adaptors -
Summary
Male To a Controller
Female 1 To an H879-AA Terminator
Female 2 To a BN21K cable
Digital UK Systems Business Technical Support Group
Howard James Tony Thompson
@REO-D1/7 @REO-D1/7
OR by electronic mail to :
Howard James @REO (ALL-IN-1) Tony Thompson @REO
Howard.James @REO.MTS.DEC.COM (Internet) Tony.Thompson @REO.MTS.DEC.COM
Back to VAXarchive hardware